Air conditioning systems.

Abstract

There are some basic requirements for air conditioning systems in operating theatres. 1. Obviously the regulation of temperature and humidity is necessary, but cleaning of fresh air and circulating air is much more important. 2. Concerning cleaning, a high standard of filtration of air is demanded to avoid contamination of wounds. 3. So far only HEPA-filters, a technical description, give security and safety. They filter particles down to under 1 micrometer and have a filtration rate of more than 99.9%. 4. The ventilation rate is directly related to the germ concentration in the air. The higher the ventilation rate the cleaner the air during working. 5. To avoid turbulences unidirectional or uniform flow is necessary. This technique has become popular as the laminar flow technique. To get such a flow an air flow velocity of 0 45 +/- 0.1 m/s is necessary. 6. The arrangement of the different working places in an operating theatre is very important. Instrument tables and the operation field itself have to be in the zone of first air. 7. One of the commonest germ dispersion sources is the human body. Proper dressing and behaviour have to be observed. The airflow behind a person (in laminar cross flow) or under a person (in laminar down flow for instance when the neurosurgeon bends his head over the operating field) has to be regarded as contaminated. 8. Hygienic controls must be made in the operation theatre when unused and also under working conditions, in a sophisticated manner. If all these points are respected a real clean room technique is possible with considerable lowering of the risk of infection for the patient. Obviously all the other rules of hygiene, i.e., asepsis and antisepsis, elaborated since the days of Lister, have to be strictly respected.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Lorenz. 1980. Air conditioning systems.. https://doi.org/10.1007/bf01808920

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Field trial of biocides for control of Legionella in cooling towers.

Legionella and amebae populations in 16 cooling towers were challenged with three commercially available biocide formulations. The active agents were: a chlorinated phenolic thioether (CPTE), bromo-nitro-propane-diol (BNPD), and bromo-chloro-dimethylhydantoin (BCD, in briquette form). The towers were dosed with these biocides for approximately 4 weeks. BCD was effective against Legionella in each of nine challenge experiments, and CPTE in eight of nine challenges. BNPD was effective in only five of 11 challenges. None of the biocides had any significant effect in reducing planktonic amebae concentrations during the challenges.

Air Conditioning

Fungal colonization of air filters for use in heating, ventilating, and air conditioning (HVAC) systems.

New and used cellulosic air filters for HVAC systems including those treated with antimicrobials were suspended in vessels with a range of relative humidities (55-99%) and containing non-sterile potting soil which stimulates fungal growth. Most filters yielded fungi prior to suspension in the chambers but only two of 14 nontreated filters demonstrated fungal colonization following use in HVAC systems. Filters treated with antimicrobials, particularly a phosphated amine complex, demonstrated markedly less fungal colonization than nontreated filters. In comparison with nontreated cellulosic filters, fungal colonization of antimicrobial-treated cellulosic filters was selective and delayed.

Air Conditioning