PubMed HealthSearch

PubMed · 7234687

Multiple-pulse laser retinal damage thresholds.

Abstract

The additivity from multiple exposures of the retina to laser light sources is investigated with regard to empirical and theoretical models. Prior data indicate additivity consistent with a total-on-time formulation in the case of point source conditions but not for extended source conditions. Thermal model calculations agree with the extended source results, but only agree with point-source data when the pulse repetition rate is higher than 10 Hz. The anomaly at low pulse repetition rates can still be interpreted in terms of a thermal damage mechanism if spatial variations are considered.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G A Griess, M F Blankenstein. 1981. Multiple-pulse laser retinal damage thresholds.. https://doi.org/10.1080/15298668191419749

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Quantitative comparison of excited state properties and intensity- dependent photosensitization by rose bengal.

A quantitative (multistep) excitation-deactivation model of rose bengal (RB) has been developed which includes energy and electron transfer to oxygen and the possibility of photoproduct formation via higher excited triplet-singlet states. The model is based on previous measurements of non-linear absorption (NLA) and emission of RB with picosecond pulses at 532 nm and on NLA measurements with nanosecond pulses. A coupled rate equation and photon transport equation approach for non-linear light-matter interaction is used. The resulting term scheme with all relevant excited state parameters confirms that (i) in the first excited state of RB, relevant absorption at 532 nm takes place only in the triplet, and (ii) the previously reported intensity dependence of RB-sensitized enzyme inhibition is well modelled by the intensity-dependent RB-T1 population and (as the main process) subsequent energy transfer to form singlet oxygen.

Lasers

Characterization of oligomers in poly(ethylene terephthalate) by matrix-assisted laser desorption/ionization mass spectrometry.

Matrix-assisted laser desorption/ionization mass spectrometry was used for the characterization of extracted and synthesized oligo(ethylene terephthalate)s. Generally, cyclic oligomers [GT]n could be found in technical yarns and tiles, whereas our synthesized model oligomers mainly consisted of linear chains H-[GT]n-G. In addition, some other distributions could be identified as H-[GH]n-OH and H-[GGT]1-[GT]n-7/-G linear oligomers and H-[GGT]1-[GT]n-1 cyclic oligomers, where G is an ethylene glycol unit, GG is a diethylene glycol unit, caused by impurities of ethylene glycol, and T is a terephthalic acid unit. NMR and IR investigations were carried out to verify these results.

Lasers

Effects of the picosecond neodymium:YLF laser on poly(methyl methacrylate) intraocular lenses during experimental posterior capsulotomy.

We evaluated the effect of the neodymium:YLF picosecond laser on intraocular lenses (IOLs) during experimental posterior capsulotomy and established the minimum damage threshold for lathe-cut poly(methyl methacrylate) (PMMA) IOLs. Single-piece, biconvex, lathe-cut PMMA lenses were placed in a model eye chamber against a latex membrane with a central area of lens-capsule touch. Energy levels from 40 micro J to 360 microJ pulse (0.4 mJ to 3.6 mJ) with a 0.5 mm line and a spot pattern were tested using different focal offsets. Threshold damage level was determined under the scanning electron microscope after observing the minimal energy level that did not cause damage to or pits in the IOLs. Lenses were then analyzed for size and type of damage. The 0.5 mm line pattern at 160 microJ using 350 microns offset was safe and effective for posterior capsulotomy in vitro. spot pattern caused IOL damage in the form of small pits at much lower energy levels of 80 microJ using 400 microns offset than the line pattern.

Lasers