PubMed Health⌕ Search

PubMed · 7239103

[Study of left ventricular function in chronic volume overload (author's transl)].

Abstract

Have been studied 51 patients with aortic incompetency (AI), 46 with mitral insufficiency (MI) and 31 with congestive cardiomyopathy (CM) as example of a primitive myocardial lesion. The mean parametres calculated were: the left ventricular end-diastolic pressure (LVEDP), the ventricular volumes, the ejection fraction (EF), the end-sistolic pressure-volume ratio (Emax) and the eccentricity. In the chronic volume overload, the relationship between the pump performance and the contractility (EF-Emax) is parabolic with an initial plateau (myocardial failure without circulatory failure); the EF-Emax relationship, in the CM, is linear without a plateau. The LVEDP is a limiting factor of the pump-contractility relationship in the AI: for the same value of the contractility, the pump function is greater depressed if the LVEDP is 25 mmHg (loss of the preload modulation); in the MI and CM the depression of the pump performance is a function only of the depressed contractility. The end-systolic eccentricity is correlated with Emax: the changes in the geometrical shape of the left ventricular chamber is due to the depressed contractility.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Scognamiglio, R Chioin, P Stritoni, R Razzolini, L Daliento, F Corbara, G M Boffa. 1981. [Study of left ventricular function in chronic volume overload (author's transl)].. https://pubmed.ncbi.nlm.nih.gov/7239103/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study.

OBJECTIVE: The aim of this report is the prospective, multicentre evaluation of clinical results and haemodynamic performance of the Medtronic Advantage aortic valve prosthesis. METHODS: From April 2001 to June 2003, 166 patients (male:female 125:41; mean (SD) age 61.8 (11.8) years) received an aortic advantage valve prosthesis. Complete cumulative follow-up was 242.7 patient-years (maximum 3.2; mean 1.6 years). Postoperatively, patients underwent early (within 30 days) and 1 year transthoracic echocardiography. RESULTS: 30 day mortality was 2.4% (n = 4). Kaplan-Meier estimates of freedom from complications and linearised rates were as follows: 96.9 (1.6)% survival; 94.7 (1.3)% (2.06 patients/year) thrombo-embolism; 99.4 (0.6)% (0.4 patients/year) bleeding; 98.8 (0.9)% (0.8 patients/year) non-structural valve dysfunction; 98.8 (0.9)% (0.8 patients/year) reoperation. Valvular mean pressure gradients ranged from 16 (3) mm Hg for size 19 to 7 (2) mm Hg for size 27 and the corresponding effective orifice areas ranged from 1.2 (0.25) to 3.2 (0.66) cm(2). In all, left ventricular mass significantly decreased (p<0.001) and fractional shortening increased (p<0.001) from postoperative to 1 year echocardiography. CONCLUSIONS: Haemodynamic performance and early clinical results of Medtronic advantage in the aortic position were satisfactory and comparable with those of other bileaflet valves in current clinical use.

Aortic Valve Insufficiency↗

Aortic insufficiency due to a partial left-coronary aortic valve prolapse and the detection of two small interatrial jets after blunt thoracic trauma.

Aortic valve regurgitation due to blunt thoracic trauma is a rare complication. Autopsy studies have been shown that the aortic valve is the most often lacerated one among the heart valves. Actually, we describe a case of a 47 year old man with the signs of heart failure after a blunt thoracic trauma 2 months before caused by aortic insufficiency due to a partial left-coronary aortic valve prolapse. Furthermore, transthoracic and transesophageal echocardiography revealed two small jets between the left and the right atrium.

Aortic Valve Insufficiency↗