Detection of immune complexes using a solid-phase C1q polystyrene ball assay.

Abstract

A polystyrene ball C1q solid-phase assay (PSB C1q SPA) has been developed for quantitating immune complexes in human serum. While similar to the previously reported solid-phase C1q assays in principle, the use of polystyrene balls with a specular finish has resulted in an assay with significantly improved accuracy, sensitivity and reproducibility. The sensitivity of the assay based on the amount of AHGG bound per microgram C1q added was approximately 12-fold higher in the PSB assay compared to the polystyrene tube solid-phase C1q method. In order to correct for variable background contributions in different samples, values obtained with heat-inactivated C1q were subtracted from each experimental result. Reproducibility studies yielded a coefficient of variation (CV) of 10 and 4% in day-to-day assays using 25 microgram and 100 microgram AHGG/ml normal serum, respectively compared to 11--15% for the tube technique. Within run measurements gave a CV of 37 and 20% at the low and high levels of AHGG. Aggregated human gamma-globulin (AHGG) was used as a model immune complex and when chromatographed on Biogel A-15m yielded major fractions at greater than or equal to 15,000,000 and 150,000 daltons. Maximum binding of AHGG to PSB C1q occurred with aggregates greater than 15,000,000 daltons. Optimum binding of human albumin-anti-albumin complexes in the PSB C1q SPA occurred at a molar ratio of 1 : 1.5. The size distribution of this complex active in the assay determined by sucrose density gradients was 14--32 S with peaks at 21 and 27 S. A normal range of immune complexes was determined as 15 +/- 8 microgram AHGG equivalents (+/- 2 S.D., n = 65). Approximately 70% of rheumatoid arthritis, linear scleroderma, vasculitis, Sjögren's and glomerulonephritis and 40% of SLE patients were above 2 S.D. of normal. SLE patients demonstrated elevations in immune complexes only during periods of increased disease severity. The assay was a useful monitor of plasmapheresis in an SLE patient, showing decreases in immune complexes after each plasmapheresis. DNA did not interfere with AHGG binding whereas lipemia prevented detection of added AHGG.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D A Pohl, C C Tsai, S T Roodman. 1981. Detection of immune complexes using a solid-phase C1q polystyrene ball assay.. https://doi.org/10.1016/0022-1759(81)90363-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune complexes suppress IFN-gamma signaling by activation of the FcgammaRI pathway.

Antigen-driven immune responses are modulated by immune complexes (ICs), in part through their ability to inhibit IFN-gamma-dependent MHC Class II expression. We have demonstrated previously that ICs dramatically inhibit IFN-gamma-induced activation of human monocytes through the suppression of the JAK/STAT signaling pathway. In the current study, we further explore the mechanisms by which ICs regulate IFN-gamma activation of human monocytes. Consistent with previous studies in monocytes pretreated with ICs, there was a reduction in steady-state levels of RNA by real-time RT-PCR of the IFN-inducible protein 10 gene as well as the FcgammaRI gene. Pull-down assays confirm that IC pretreatment inhibits IFN-gamma-induced STAT1 phosphorylation without affecting the ability of STAT1 to bind to the STAT1-binding domain of the IFN-gamma receptor. In addition, the inhibitory function of ICs was reduced when cells from the FcR common gamma-chain knockout mice were used, supporting the role of the FcgammaRI in this inhibitory pathway. It is unexpected that ICs also require the phosphatase Src homology-2-containing tyrosine phosphatase 1 (SHP-1) to inhibit IFN-gamma induction, as demonstrated by studies with cells from the SHP-1 knockout (motheaten) mice. These data suggest a mechanism of IC-mediated inhibition of IFN-gamma signaling, which requires the ITAM-containing FcgammaRI, as well as the ITIM-dependent phosphatase SHP-1, ultimately resulting in the suppression of STAT1 phosphorylation.

Antigen-Antibody Complex↗

Immuno-mass spectrometry assay of EPI-HNE4, a recombinant protein inhibitor of human elastase.

In order to increase the sensitivity of liquid chromatography/mass spectrometry (LC/MS) assays of recombinant proteins for pharmacokinetics studies, we have developed an immuno-mass spectrometry assay for EPI-hNE4, a 6237 Da protein currently developed for respiratory distress syndromes. After immunocapture of the analyte in human plasma with magnetic beads coated with anti-EPI-hNE4 antibodies, the intact protein was eluted and separated in reversed-phase LC and then analysed by tandem mass spectrometry (MS/MS) in selected reaction monitoring (SRM) mode. The problem of analytical interference due to endogenous binding antibodies was addressed by successive steps of acidification and neutralisation before immunocapture. Furthermore, potential variations in the recovery of analyte during sample extraction were compensated for by addition of an internal standard recognised by the antibodies. The precision of the assay remained therefore below 15%. A significant increase in assay sensitivity was achieved since the extraction step allowed sample concentration and removal of matrix components interfering with the electrospray ionisation process. Using 0.4 mL of plasma, a limit of quantification at 0.5 ng/mL (80 pM) was reached, which represents a 10-fold improvement in sensitivity over our previous work using sample precipitation. This technique was able to monitor EPI-hNE4 kinetics in the plasma of human subjects for 36 h after an intravenous administration of 0.125 mg/kg.

Antigen-Antibody Complex↗

Antibody arrays for quantitative immunophenotyping.

Detection of multiple surface antigens expressed on living cell is an important step for cell processing and clinical diagnosis. Here we describe the preparation of antibody arrays that allow parallel detection of multiple surface antigens through affinity binding of living cells. An antibody array was fabricated by photo-assisted patterning of an alkanethiol monolayer formed on a gold-coated glass plate and subsequent immobilization of antibodies specific for cell surface antigens in an array format. We demonstrate here that rapid phenotyping can be performed on the array for both adhesion-dependent and non-dependent cells by direct cell binding assays. The density of bound cells on each antibody spot was in accordance with their contents in an original suspension. This result suggests the feasibility of the array-based method for quantitative assessment of multiple antigen expression. These findings will serve to extend the range of fundamental and clinical applications of antibody arrays.

Antigen-Antibody Complex↗