A miniature Wright peak-flow meter.

Abstract

A new miniature Wright peak-flow meter has been designed and produced. The meter is tubular with a spring-loaded piston and a longitudinal slot through which air escapes. Its dynamic characteristics have been carefully designed to make it respond only to peak flow and not to rate of rise. Performance tests on early instruments showed fairly close correlation with the Wright peak-flow meter but with a constant error of + 38 1/min. On later models the correlation was increased to 0.990 and the error reduced to + 3%. The mini-meter correlates as well with the standard instrument as two standard instruments correlate with each other and should prove useful clinically.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B M Wright. 1978-12-09. A miniature Wright peak-flow meter.. https://doi.org/10.1136/bmj.2.6152.1627

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Evaluation of ventilatory function of the small airways].

The results of functional tests and the values of flow-volume and spirometric parameters were reevaluated in 1174 randomly selected patients with no evidence of heart disease. There were 533 patients with normal ventilation and 327 patients with no restrictive disorders. In the latter group 11% of the patients had normal FEV1 and lowered FEF50 and FEF75 values. In those patients obstructive changes would not have been found if expiratory flow rates had not been taken into account as one of the criteria for evaluating airway obstruction. In further 13% of the patients a mild airway obstruction would have been found had only FEV1 been evaluated without taking account of expiratory flow rates. It is concluded that expiratory flow rates along with anamnestic data and clinical status are important indicators of obstructive changes of ventilation, especially as they serve to identify functional disorders while these are still reversible and therapy can be useful.

Forced Expiratory Flow Rates

Pulmonary function in newborns after repair of congenital diaphragmatic hernia.

Congenital diaphragmatic hernia (CDH) is associated with pulmonary hypoplasia that limits survival, but the nature and extent of pulmonary dysfunction in neonates with CDH have not been studied. We performed pulmonary function tests (PFTs) in eight intubated infants who survived neonatal repair of CDH (wt, 3.33 +/- 0.15 kg; age, 20.1 +/- 2.7 d; mean +/- S.E.M.). PFTs obtained from six full-term infants (wt, 3.56 +/- 0.15 kg; age, 25.0 +/- 3.3 d) with no respiratory illness served as controls. The deflation flow-volume curve technique produced maximum expiratory flow-volume (MEFV) curves, giving reproducible measurements of forced vital capacity (FVC) and maximal expiratory flow at 25% of FVC (MEF25). Respiratory system compliance (Crs) and resistance (Rrs) were obtained with a modified passive mechanics technique. In seven of eight infants PFTs were repeated after nebulized bronchodilator (0.1% isoetharine). In neonates surviving CDH repair, as compared to those with normal lung function, FVC was significantly reduced (20.78 +/- 3.32 vs. 39.83 +/- 3.30 mL.kg-1, P less than 0.05). MEF25 was also markedly reduced (20.78 +/- 3.32 vs. 39.83 +/- 3.30 mL.kg-1.s-1, P less than 0.05), indicating lower airway obstruction. After administration of nebulized bronchodilator, PFTs showed significant increases from control values in both FVC (15.9%) and MEF25 (200%) without changes in Crs and Rrs. These findings indicate that neonates with CDH have restrictive lung defects, reflecting hypoplasia. After surgical repair and mechanical ventilation airway reactivity develops, primarily in smaller airways, and this may complicate the postoperative course.

Forced Expiratory Flow Rates