PubMed · 7290024
Lead shielding for electrons.
Abstract
Using a 13 MeV electron beam as an example, transmission curves for various thicknesses of lead were measured. The data indicated that the choice of shielding thickness depends greatly on the depth at which the measurements are made. The importance of this reference depth and criteria for shield design when shields of minimum thickness are required is discussed.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
F M Khan, B L Werner, F C Deibel. Lead shielding for electrons.. https://doi.org/10.1118/1.594841. https://pubmed.health/record/pubmed%3A7290024/lead-shielding-for-electrons