Hip arthroplasty by matching cups.

Abstract

A total hip surface arthroplasty consisting of matching cups and uncemented prosthetic components is a noteworthy operation. The femoral cup obtains cylindrical support from the femoral head which is reamed in the shape of a cylinder. The acetabular cup is metallic with a polyethylene liner. It is mobile over the bone but its position is constrained by contact with the femoral cup and therefore "self-centering." On the femoral side, the cup must be placed strictly in the axis of the femoral neck. The main consideration in femoral head surface replacement is the vitality of the underlying bone. Necrosis was observed in the earliest clinical trials but there have been no cases of necrosis in the past 3 1/2 years. This is attributed to a more limited surgical approach in which only the anterior part of the gluteus medius is divided and all the posterior elements of the hip are preserved. The acetabulum is sufficiently reamed to receive the cup, which protrudes beyond the external margins of the acetabulum in all positions. Errors have been committed while perfecting the prosthetic material, but the results as determined by a 6 1/2 year follow-up on purely metallic cups are encouraging. Metal-polyethylene cups presently under investigation have almost a 2 year follow-up. The reaction of the acetabulum to an uncemented cup is not yet known. However, the existence of 2 sliding surfaces and the fact that the acetabular cup moves only during the extremes of hip movement, is reason to assume that if the acetabulum is not reamed to expose cancellous bone, the risks of protrusion are minimal or delayed. Total surface arthroplasty by concentric cups has been performed in 335 hips to date. The operation is especially recommended when osteotomy is no longer possible and disabling coxarthrosis is present in relatively young patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Gerard. Hip arthroplasty by matching cups.. https://pubmed.ncbi.nlm.nih.gov/729253/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acetabular reinforcement in total hip replacement.

In conclusion, based on our experimental and clinical material and analysis of failures, we recommend wire mesh reinforcement and bone graft for patients with mild to moderate protrusio. If the floor is strong but the pillars deficient, then the Eichler ring alone is the best implant. The combined system of wire mesh and Eichler ring should be used in cases of protrusion with a large deficiency of the acetabular floor and for protrusio with pillar weakness. Furthermore a bone graft should be used to reinforce the acetabular floor in addition to any prosthetic device.

Acetabulum

Influence of cartilage geometry on the pressure distribution in the human hip joint.

To elucidate the role of mechanical factors in the etiology of osteoarthritis, the detailed geometry of the weight-bearing cartilage layer over the human hip socket is compared with the corresponding pressure distribution. The shape of the pressure distribution is strongly correlated with the shape of the cartilage compression distribution.

Acetabulum