PubMed HealthSearch

PubMed · 7316596

Temporary pacemaker wire insertion: a simple, safe, and effective technique.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J R Edgerton, D G Knauf, J A Alexander. 1981. Temporary pacemaker wire insertion: a simple, safe, and effective technique.. https://doi.org/10.1016/s0003-4975(10)61809-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Antitachycardia pacing: which patients and which methods?

This article is a review on the value of antitachycardia pacing in patients with implantable cardiac-defibrillators (ICD). Antitachycardia pacing is highly effective in terminating monomorphic ventricular tachycardias, with a success rate of 80-90%. Which algorithm is used for termination seems to be of less importance, with respect to both efficacy and safety. Spontaneous episodes of ventricular tachycardia are slower and more easily convertible than those induced by programmed stimulation. It is thus possible that fine-tuning of the antitachycardia pacing algorithm, using induced episodes, is of limited value with respect to efficacy during follow-up. Prospective studies need to be performed to resolve this issue. Spontaneous monomorphic ventricular tachycardia can also occur in patients who are noninducible. Antitachycardia pacing should therefore also be considered for such patients. Inappropriate therapy, most often due to supraventricular arrhythmias, has been reported in up to 25% of patients. The sensitivity and specificity of algorithms developed to differentiate supraventricular from ventricular tachycardias still require validation.

Cardiac Pacing, Artificial

A patient with syncopal ventricular tachycardia (noninducible on electrophysiologic study) and coronary artery disease.

The case of a 63-year-old patient with coronary artery disease presenting with syncopal sustained ventricular tachycardia is reported. He had very poor ventricular function, an extensive myocardial scar, and limited area of reversible ischemia. Coronary angiographic examination showed a left main equivalent coronary artery disease with critical stenosis. Although this patient should theoretically benefit from revascularization, we decided against this due to the high estimated perioperative mortality rate for coronary artery bypass grafting in such a patient. Therefore, we intensively treated myocardial ischemia and pump failure with digoxon, furosemide, dihydralazine, nitrates, and warfarin and prescribed a back-up defibrillator implant.

Cardiac Pacing, Artificial