Abstract

Avcothane is a commercially available copolymer of polyether, polyurethane, and polydimethylsiloxane; it is used primarily in aortic balloon pumps. The pumps consist of three segments which are cemented or fused together to form the balloon. The objective of this work is to characterize the surfaces, inside and outside, of the three balloon pump sections. By using x-ray photoelectron spectroscopy (ESCA), ion scattering spectroscopy (ISS), and secondary ion mass spectrometry (SIMS) a detailed analysis of the Avcothane surfaces can be performed and comparisons between various surfaces made. Previous workers have reported ESCA and Auger electron spectroscopy (AES) measurements of Avcothane and comparisons with their results will be presented. SIMS and ISS are useful analytical tools for studying polymeric biomaterials because these techniques are usually more surface sensitive than either ESCA or AES. SIMS and ISS data indicate that a thin fluorine-rich film (probably a fluorocarbon polymer) is present on the Avcothane surface. Signals from the fluorine-rich layer are more intense from the inside of the balloon pump and the intensity generally decreases from top to bottom. The outside sections of the aortic balloon pump also show the presence of fluorine, but the signals are far less intense than from the inside. One possible explanation for the fluorine-rich layer is that a fluorine-containing compound is deposited on the balloon pump during molding and preparation. Another possibility is that the layer is deposited during preparation of the Avcothane itself, but is essentially removed from the outside during sterilization.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S W Graham, D M Hercules. 1981. Surface spectroscopic studies of Avcothane.. https://doi.org/10.1002/jbm.820150307. https://pubmed.health/record/pubmed%3A7348270/surface-spectroscopic-studies-of-avcothane

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Percutaneous endocardial and epicardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory.

Ventricular tachycardia (VT) in the setting of structural heart disease is challenging to treat with percutaneous catheter ablation due to the presence of complex substrate, multiple morphologies, hemodynamic instability, and epicardial circuits. When substrate-based approaches fail, however, it may be impossible to map and ablate hemodynamically unstable arrhythmias. We describe a novel approach to endocardial and epicardial mapping and ablation of hypotensive VT using a percutaneous left ventricular assist device in the electrophysiology laboratory, permitting near-surgical access to cardiac structures.

Assisted Circulation↗

IgG classification of anti-PF4/heparin antibodies to identify patients with heparin-induced thrombocytopenia during mechanical circulatory support.

Commercial immunoassays frequently detect anti-PF4/heparin antibodies during mechanical circulatory support (MCS), but only a small minority of patients develops heparin-induced thrombocytopenia (HIT). Whereas platelet functional tests can distinguish between platelet-activating and non-platelet-activating antibodies, commercial PF4-dependent immunoassays do not. Between 2003 and 2004, 113 patients were placed on MCS. Blood samples were obtained on postimplant day 5-7 for analyses by antibody assays and the functional heparin-induced platelet activation (HIPA) assay. Three distinct groups of patient sera were identified: platelet-activating anti-PF4/heparin antibodies (n = 10), non-platelet-activating anti-PF4/heparin antibodies (n = 53), and anti-PF4/heparin antibody negative (n = 50). Patients with platelet-activating antibodies had the highest risk for thromboembolic events (P < 0.005), whereas those with non-platelet-activating antibodies did not differ from antibody negative patients (P = 0.369). The enzyme-immunoassay and column agglutination assays, which cover all immunoglobulin classes, demonstrated adequate sensitivity and negative predictive value; yet, both lacked specificity with respect to the platelet-activating antibodies. If all antibody positive patients were further classified by an IgG-specific anti-PF4/heparin enzyme-immuno assay, specificity for platelet-activating antibodies increased. Whereas IgG-specific optical density (OD) values below 1.0 were likely for non-platelet-activating anti-PF4/heparin antibodies, higher values were progressively predictive for pathogenic platelet activation. The probability of the development of clinical HIT also increased steeply. In conclusion, platelet-activating anti-PF4/heparin antibodies are relatively common (about 9%) in patients on MCS and are associated with significantly higher thrombotic event rates. Low IgG-specific OD values (< 1.0) in the enzyme-immunoassay indicate low likelihood for the presence of platelet-activating antibodies. These results justify further validation so that anticoagulation during MCS becomes safer and adequate.

Assisted Circulation↗