Evaluating commercially available spirometers.

Abstract

This study was designed to: (1) determine the performance characteristics of available spirometers; (2) assess the practically and applicability of the American Thoracic Society's (ATS) Snowbird Workshop recommendations on Standardization of Spirometry; and (3) determine whether spirometer testing could be done with room air. Nineteen spirometers were tested with 16 different forced vital capacity waveforms. Fourteen spirometers met the ATS forced vital capacity requirements. Three of these 14 spirometers had difficulties in determining the end of expiration. Fourteen of the devices tested met the requirements for forced expiratory volume in one second. Ten of 13 devices tested for maximal voluntary ventilation were satisfactory. The standards recommended by ATS were believed to be applicable and practical. The testing methods recommended by ATS need to be expanded to include more patient waveforms. Testing with room air is easier and simpler and, for most devices, just as effective as heated and humidified air. We conclude that most available spirometers can faithfully record forced spirograms and that if a spirometer meets the ATS requirements, it makes no difference on which device the spirogram is recorded.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R M Gardner, J L Hankinson, B J West. 1980. Evaluating commercially available spirometers.. https://doi.org/10.1164/arrd.1980.121.1.73

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Herniography and ultrasonography. A prospective study comparing the effectiveness of laparoscopic hernia repair with extraperitoneal balloon dissection.

BACKGROUND: This study was designed to assess differences between pre- and postoperative herniography and ultrasonography in inguinal hernia performed laparoscopically with balloon dissection and mesh without suture. METHODS: Pre- and postoperative herniographic and ultrasonographic findings were analyzed in ten consecutive patients. Postoperative ultrasonography was performed on the 3rd and 7th days and herniography was performed on the 7th day. RESULTS: Following the operation both the herniography and ultrasonography were almost normalized to a great extent in nine patients. Overall, minimal impaired continence was recorded by herniography in one patient. Also, we detected nonspecific soft-tissue thickening at the operation site in ultrasonographic examination in four patients. CONCLUSIONS: As for inguinal hernias, compared with other operative modalities of treatment, laparoscopic hernia repair with extraperitoneal balloon dissection and mesh without suture is a highly successful procedure and its minimal morbidity is well accepted by the patient.

Evaluation Studies as Topic

[Evaluation of one of the third generation reagents for anti-HCV antibody measurement in comparison with three second generation methods].

It is important to measure anti-HCV antibody(HCV.Ab) in blood to diagnose and treat viral hepatitis C patients. We evaluated one of the third generation reagents, Entymun-Test anti-HCV(Boehringer mannheim), which was developed to minimize false-positive reactions, and compared these results to findings obtained with three second generation tests for HCV.Ab. Coefficients of variation in the Entymum-Test assay were good(within-run, 1.1 approximately 1.8%; between-run, 2.5 approximately 7.5%). Four interfering substances(bilirubin C, bilirubin F, lipid and hemoglobin) hardly affected the HCV.Ab measurement. The HCV.Ab indices of healthy donors(n = 61) were distributed below the cut-off index(C.O.I). Sensitivity of the third generation test was the same as that of second generation tests, calculated from the results of dilution tests. Index of the dilution test in the third generation test formed a plateau until four-fold dilution, but there was no prozone phenomenon. Among the third generation test and three second generation tests, the former had the lowest positive percentage in serum HCV.Ab. Moreover, findings of HCV-RNA agreed more with the results of the third generation test among the four tests. As a result, the third generation test appeared to minimize false-positive results and improve specificity.

Evaluation Studies as Topic