PubMed HealthSearch

PubMed · 7357727

PDA by Doppler echo.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Jenni, A Vieli. 1980. PDA by Doppler echo.. https://pubmed.ncbi.nlm.nih.gov/7357727/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Precision and accuracy of clinical and radiological signs in premature infants at risk of patent ductus arteriosus.

OBJECTIVE: To determine the precision (interobserver agreement) and accuracy (agreement with criterion standard) of clinical and radiological signs in premature infants at risk of patent ductus arteriosus (PDA) with left-to-right shunting. DESIGN: Masked comparison of clinical and radiological examination with Doppler flow echocardiography (criterion standard). SETTING: Neonatal intensive care unit. PATIENTS: One hundred infants with birth weights less than 1750 g were studied once between days 3 and 7 of life. A third of the cohort was intubated at the time of study. INTERVENTION: Five independent observers noted the presence or absence of an increased pulse volume, an active precordium, a heart murmur, a cardiothoracic ratio greater than 60%, increased pulmonary vascular markings on a concurrent chest x-ray film, and a relative increase of the cardiothoracic ratio compared with that from the previous chest x-ray film. Pulsed and color flow Doppler echocardiography was performed within 4 hours. All 100 tapes were reviewed by a second pediatric cardiologist. RESULTS: Twenty-three infants had a PDA with left-to-right shunting. The precision of clinical signs was modest, with average kappa values of 0.15 for pulse volume, 0.32 for precordium, and 0.41 for murmur. Pulse quality (43%) and murmur (42%) had the highest mean sensitivities. Corresponding specificities were 74% for pulse volume and 87% for murmur. The combination of a cardiac murmur with an abnormal pulse volume had the highest positive predictive value (77%). The radiological examination did not improve the observers' ability to distinguish between patients with and without PDA. CONCLUSIONS: The precision and accuracy of clinical and radiological signs of a PDA with left-to-right shunting are unsatisfactory. Therefore, Doppler flow echocardiography is required to diagnose PDA confidently in preterm infants between days 3 and 7 of life.

Ductus Arteriosus, Patent

Surgical treatment of transposition of great arteries with interrupted pulmonary artery: a rare association of embryopathies.

The first case of TGA with VSD, ASD, and interrupted LPA and its successful surgical treatment is being reported along with a review of the relevant literature. The dominant presenting clinical features have been explained and an attempt has been made to explain the paucity of records in regard to this embryopathy. An arterial switch for TGA and a glutaraldehyde pretreated autologous pericardial roll for repair of interrupted LPA were carried out. Pre- and postoperative hemodynamics and angiography data are also presented.

Ductus Arteriosus, Patent

Synchronous intermittent mandatory ventilation modes compared with patient triggered ventilation during weaning.

The efficacy of combining rate and pressure reduction during weaning by synchronous intermittent mandatory ventilation (SIMV) were compared with weaning by patient triggered ventilation (PTV) (pressure reduction alone) in two randomised trials. Regardless of ventilation mode, pressure was reduced to the same level according to the size of the infant. In the first trial, the SIMV rate was also reduced progressively to a minimum of 20 breaths/minute, and in the second to five breaths/minute. Forty premature infants aged 15 days of age or less were randomly allocated into each trial. No significant differences were found in the first trial between ventilation modes in either the duration of weaning or the number of infants in whom weaning failed. In the second trial, the duration of weaning was shorter by PTV than by SIMV (median 24 hours, range 7-432 v 50 hours, range 12-500; p < 0.05); weaning failed in two infants in the PTV group and in five in the SIMV group. It is concluded that weaning by a combination of pressure and rate reduction, such as can be achieved during SIMV, offers no significant advantage over pressure reduction alone.

Ductus Arteriosus, Patent