The role of Factor XIII in clot retraction was studied using the plasma from Factor XIII-deficient patients. Time course experiments revealed no significant difference in clot retraction between a plasma deficient in Factor XIII and one to which purified Factor XIII had been added. Using Factor XIII-free fibrinogen and Factor XIII-deficient platelets, it is shown that there is no significant difference in clot retraction with or without added Factor XIII.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K M Rao, T F Newcomb. 1980. Clot retraction in a factor XIII free system.. https://doi.org/10.1111/j.1600-0609.1980.tb02358.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Computer simulation of systemic circulation and clot lysis dynamics during thrombolytic therapy that accounts for inner clot transport and reaction.

BACKGROUND: We developed a computer model to predict lysis rates of thrombi for intravenous thrombolytic regimens based on the convective/diffusive penetration of reacting and adsorbing fibrinolytic species from the circulation into the proximal face of a dissolving clot. METHODS AND RESULTS: Solution of a one-compartment plasma model provided the dynamic concentrations of fibrinolytic species that served as inlet conditions for stimulation of the one-dimensional spatiodynamics within a dissolving fibrin clot of defined composition. The model predicted the circulating levels of tissue plasminogen activator (TPA) and plasminogen levels found in clinical trials for various intravenous therapies. To test the model predictions under in vitro conditions, plasma clots were perfused with TPA (0.1 mumol/L) and plasminogen (1.0 mumol/L) delivered at constant permeation velocity of 0.1 or 0.2 mm/min. The model provided an accurate prediction of the measured lysis front movement. For TPA administration regimens used clinically, simulations predicted clot dissolution rates that were consistent with observed reperfusion times. For unidirectional permeation, the continual accumulation of adsorbing species at the moving lysis front due to prior rounds of solubilization and rebinding was predicted to provide for a marked concentration of TPA and plasmin and the eventual depletion of antiplasmin and macroglobulin in an advancing (approximately 0.25 mm thick) lysis zone. CONCLUSIONS: Pressure-driven permeation greatly enhances and is a primary determinant of the overall rate of clot lysis and creates a complex local reaction environment at the plasma/clot interface. With simulation of reaction and transport, it becomes possible to quantitatively link the administration regimen, plasminogena activator properties, and thrombolytic outcome.

Clot Retraction

[Technique of intraoperative treatment of a retro-mandibular defect after parotidectomy. Use of a blot clot].

As noticed in our experience, cosmetic results, after total parotidectomy, were better if the patient presented an hematoma. The author got the idea to fill the retro-mandibular defect with a clot. The technique is presented in detail. Fifty four patients had a total parotidectomy between January 1992 and May 1993. A clot was used in 39 of these 54 cases. Were excluded malignant tumors, superficial parotidectomies or the presence of a general pathology (diabetes, cirrhosis). The result was excellent in 31 cases even if a local treatment was necessary due to a secondary hematoma. There was no infectious complication. The follow-up of this series is insufficient, but by analogy with spontaneous hematoma, the results should be persistent. This technique is simple, does not increased the time of the surgical procedure and does not induced injury on any donor site.

Clot Retraction

Effect of retraction on the lysis of human clots with fibrin specific and non-fibrin specific plasminogen activators.

The effect of the serum content of human clots on their sensitivity to lysis with plasminogen activators was studied in a system composed of 125I-fibrin labeled clots immersed in buffer or in citrated plasma. The effect was studied with plasma clots before or after mechanical compression and with whole blood clots before or after retraction, using either the fibrin specific plasminogen activators recombinant tissue-type plasminogen activator (rt-PA) or recombinant single chain urokinase-type plasminogen activator (rscu-PA), and the non-fibrin specific activators recombinant two chain urokinase-type plasminogen activator (rtcu-PA), or streptokinase (SK). In a buffer milieu, all plasminogen activators had a similar fibrinolytic potency towards serum-rich clots (non-compressed plasma clots or non-retracted blood clots): 50% clot lysis in 4 h required 50 to 85 ng plasminogen activator per ml. Serum-poor clots (compressed plasma clots or retracted blood clots) were resistant to lysis in a buffer milieu but became sensitive to lysis following preincubation in plasma for 48 h. These findings indicate that plasma proteins entrapped in clots contribute significantly to their sensitivity to lysis and suggest that the amount of bound or entrapped plasminogen may be a limiting factor. In a plasma milieu, all plasminogen activators lysed serum-rich plasma or blood clots, albeit at higher concentrations (3 to 40 times higher than in the buffer milieu) and with different efficiencies: 50% clot lysis in 4 h required approximately 600 ng/ml of rtcu-PA but 1,500 to 2,000 ng/ml of rscu-PA.(ABSTRACT TRUNCATED AT 250 WORDS)

Clot Retraction