PubMed Health⌕ Search

PubMed · 738888

Digital neutron dosimeter.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P W Ramondetta, E O Groeber. 1978. Digital neutron dosimeter.. https://doi.org/10.1097/00004032-197812000-00010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Monte Carlo calculations of thermal neutron capture in gadolinium: a comparison of GEANT4 and MCNP with measurements.

GEANT4 is a Monte Carlo code originally implemented for high-energy physics applications and is well known for particle transport at high energies. The capacity of GEANT4 to simulate neutron transport in the thermal energy region is not equally well known. The aim of this article is to compare MCNP, a code commonly used in low energy neutron transport calculations and GEANT4 with experimental results and select the suitable code for gadolinium neutron capture applications. To account for the thermal neutron scattering from chemically bound atoms [S(alpha,beta)] in biological materials a comparison of thermal neutron fluence in tissue-like poly(methylmethacrylate) phantom is made with MCNP4B, GEANT4 6.0 patch1, and measurements from the neutron capture therapy (NCT) facility at the Studsvik, Sweden. The fluence measurements agreed with MCNP calculated results considering S(alpha,beta). The location of the thermal neutron peak calculated with MCNP without S(alpha,beta) and GEANT4 is shifted by about 0.5 cm towards a shallower depth and is 25%-30% lower in amplitude. Dose distribution from the gadolinium neutron capture reaction is then simulated by MCNP and compared with measured data. The simulations made by MCNP agree well with experimental results. As long as thermal neutron scattering from chemically bound atoms are not included in GEANT4 it is not suitable for NCT applications.

Fast Neutrons↗

Particle matters.

Explore the source record for details and available documents.

Fast Neutrons↗

PIN silicon diode fast neutron detector.

Two batches of diodes, with different structural ratios (the ratio of area and thickness), were made using different manufacturing processes. The energy response of the first batch to 15 kinds of monoenergetic neutrons ranging from 180 keV to 17.56 MeV was tested, and the neutron source response of both batches to 239Pu-Be neutron source was measured. The energy deposition in the diodes irradiated by 1 keV to 20 MeV monoenergetic neutrons was calculated with simulation procedure. The response curve of the experimental results showed an approximately similar trend to that of theoretical computation. Based on the results of the neutron source response experiments, it was concluded that the response of fast neutron varied linearly with the structural ratio of the detectors.

Fast Neutrons↗