An algorithm for visual fields.

Abstract

The authors present an algorithm, or sequential strategy, for the performance and interpretation of visual fields. Based on the principle that particular areas of the visual field are relatively vulnerable and that particular defect configurations are relatively more diagnostic, the strategy proposes certain "core maneuvers" for all initial examinations, followed by selective exploration of the vertical meridian "rectangle" and central "keyhole." This constitutes the "qualitative" portion of perimetry and combines threshold kinetic and suprathreshold static techniques. If time and patience permit, qualitative perimetry is followed by quantiative definition of defect size, depth and slope, using the requisite number of stimuli. This approach may be adapted to all visual field instruments. The interpretation of the field defects is based on assessing their localizing features.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D Trobe, P C Acosta. An algorithm for visual fields.. https://doi.org/10.1016/0039-6257(80)90124-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The preprocessing of retinal images for the detection of fluorescein leakage.

Images of the human retina are routinely used in clinical practice for the diagnosis and management of eye disease. Increased permeability of retinal blood vessels, which is a clinically significant feature, can be visualized with a process known as fluorescein angiography as leakage of fluorescence dye into the surrounding tissues. Analyses of such images can be quantified but significant degradation of images due to uneven illumination or occluded optical pathways is often incurred during image capture. We describe a procedure to restore fluorescein angiographic retinal images so that quantitative computation can be reliably performed. Analysis of the image acquisition system reveals that captured images are composed of two functions, one describing the true underlying image and the other the degradation incurred. These two functions are independent of one another and it is possible to estimate the degradation from an isolated captured image and restore it appropriately. Any leakage of fluorescein dye is then detected by analysing the restored angiographic sequence over time and finding areas of the image that do not have the usual decrease in fluorescence intensity.

Eye Diseases