Internal analytical quality control using the cusum chart and truncated V-mask procedure.

Abstract

It is recommended that quality control data be recorded on a standard form to facilitate calculation of the cusum increments and of the cumulative sums (cusums) for plotting on the cusum chart. The 'in control' and 'out of control' judgements are made with the aid of a truncated V-mask. Full details of calculation procedures are described without recourse to statistical theory so that the cusum and truncated V-mask procedure may be carried out by operators without training in statistics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R W Edwards. 1980. Internal analytical quality control using the cusum chart and truncated V-mask procedure.. https://doi.org/10.1177/000456328001700409

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Content uniformity and assay requirements in current regulations.

The acceptance of a tablet batch is based both on the content uniformity test and on the assay. It is shown that these two characteristics are not independent, and the acceptance criteria for them are not even consistent. For content uniformity range three methods of calculation are compared: the present European Pharmacopoeia method, a tolerance range method with improved k tolerance factor and a one-way random effects analysis of variance model. To resolve the inconsistency several options are discussed: applying the holistic content uniformity range alone; using content uniformity standard deviation and assay mean simultaneously or applying a criterion based on Taguchi's quadratic loss function.

Mathematics↗

Stable time filtering of strongly unstable spatially extended systems.

Many contemporary problems in science involve making predictions based on partial observation of extremely complicated spatially extended systems with many degrees of freedom and with physical instabilities on both large and small scale. Various new ensemble filtering strategies have been developed recently for these applications, and new mathematical issues arise. Because ensembles are extremely expensive to generate, one such issue is whether it is possible under appropriate circumstances to take long time steps in an explicit difference scheme and violate the classical Courant-Friedrichs-Lewy (CFL)-stability condition yet obtain stable accurate filtering by using the observations. These issues are explored here both through elementary mathematical theory, which provides simple guidelines, and the detailed study of a prototype model. The prototype model involves an unstable finite difference scheme for a convection-diffusion equation, and it is demonstrated below that appropriate observations can result in stable accurate filtering of this strongly unstable spatially extended system.

Mathematics↗