PubMed · 7440977
Evaluation of different methods for detecting circulating immune complexes. An inter-laboratory study.
Abstract
Forty serum samples of healthy blood donors and 60 sera of SLE patients were tested in parallel by 7 different assays for detecting immune complexes. Significantly higher titres and significant higher incidence of positive results were observed in the patient group than in the control group in 6 tests. No test discriminated between patients in an active stage of the disease and those whose disease was inactive. Significantly higher immune complex levels were found in lupus nephritis than in the non-nephritic patients by the complement consumption test. Significant positive correlation was obtained between the results of the macrophage aggregated IgG uptake inhibition and PEG-precipitation tests and between two tests based on the interaction of the complexes with the complement system. A characteristic 'profile' of the immune complex assay was observed in the course of the repeated testings of the same patients. The results indicate that the different methods detect different types of immune complexes present in the blood of the patients.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
G Füst, M Kavai, G Szegedi, K Meretey, A Falus, A Lenkey, M Misz. 1980. Evaluation of different methods for detecting circulating immune complexes. An inter-laboratory study.. https://doi.org/10.1016/0022-1759(80)90276-8