PubMed HealthSearch

PubMed · 7442111

[Theoretical values for left ventricular ejection time during weightlessness].

Abstract

The relationship between duration of blood ejection and cardiac cycle at rest can be well described by a linear function. This relationship is maintained in weightlessness as well. The derived formula used in calculations of the theoretical values of the ejection phase during an exposure to LBNP makes it possible to predict LBNP test tolerance in the weightless state. The level of deviation of factual values of heart rate from theoretical values may be an additional index to be used in assessing health status of crewmembers inflight.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

V A Degtiarev, N A Lapshina, L Ia Andriiako. [Theoretical values for left ventricular ejection time during weightlessness].. https://pubmed.ncbi.nlm.nih.gov/7442111/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Left-ventricle boundary detection from nuclear medicine images.

We present here a new algorithm for segmentation of nuclear medicine images to detect the left-ventricle (LV) boundary. In this article, other image segmentation techniques, such as edge detection and region growing, are also compared and evaluated. In the edge detection approach, we explored the relationship between the LV boundary characteristics in nuclear medicine images and their radial orientations: we observed that no single brightness function (eg, maximum of first or second derivative) is sufficient to identify the boundary in every direction. In the region growing approach, several criteria, including intensity change, gradient magnitude change, gradient direction change, and running mean differences, were tested. We found that none of these criteria alone was sufficient to successfully detect the LV boundary. Then we proposed a simple but successful region growing method--Contour-Modified Region Growing (CMRG). CMRG is an easy-to-use, robust, and rapid image segmentation procedure. Based on our experiments, this method seems to perform quite well in comparison to other automated methods that we have tested because of its ability to handle the problems of both low signal-to-noise ratios (SNR) as well as low image contrast without any assumptions about the shape of the left ventricle.

Heart Ventricles

Theoretical basis for sodium and potassium MRI of the human heart at 1.5 T.

Knowledge of the extent and location of viable tissue is important to clinical diagnosis. In principle, sodium (23Na) and potassium (39K) MRI could noninvasively provide information about tissue viability. In practice, imaging of these nuclei is difficult because, compared with water protons (1H), 23Na and 39K have lower MR sensitivities (9.2 and 0.051%, respectively), and lower in vivo concentrations (ca. 1000-fold). On the other hand, the relatively short T1 relaxation times of 23Na and 39K (ca. 30 and 10 ms, respectively) suggest that optimized imaging pulse sequences may in part alleviate the weak signal of these nuclei. In this study, numerical simulations of high-speed imaging sequences were developed and used to maximize 23Na and 39K image signal-to-noise ratio (SNR) per unit time within the constraints of existing gradient hardware. The simulation demonstrated that decreasing receiver bandwidth at the expense of echo time (TE) results in a substantial increase in 23Na and 39K image SNR/time despite the short T2 and T2* of these nuclei. Referenced to the available 1H signal on existing 1.5 T scanners, the simulation suggested that it should be possible to acquire three-dimensional 23Na images of the human heart with 7 x 7 x 7 mm resolution and 39K images with 26 x 26 x 26 mm resolution in 30 min. Experimentally in humans at 1.5 T, three-dimensional 23Na images of the heart were acquired in 15 min with 6 x 6 x 12 mm resolution and signal-to-noise ratios of 11 and 7 in the left ventricular cavity and myocardium, respectively, which is very similar to the predicted result. The results demonstrate that by choosing imaging pulse sequence parameters that fully exploit the short relaxation times of 23Na and 39K, potassium MRI is improved but remains impractical, whereas sodium MRI improves to the point where 23Na imaging of the human heart may be clinically feasible on existing 1.5 T scanners.

Heart Ventricles