[Programmable and universally controlled electronic bicycle ergometer].

Abstract

A bicycle ergometer was constructed which, for the first time, allows the universal application of modern dynamic test procedures for the analysis of the regulatory behaviour and the physical working capacity in man. Different programs with impulse, step, ramp or sinusoidal test signals as well as with optimal multifrequent binary test signal sequences can be generated by a programmable automatic control system or by a function generator. In the automatic control system the signals are stored on punched papers and transformed into a voltage variation by a paper-tape reader. The voltage fluctuation is changed into the required brake horsepower of the ergometer by a special transducer. The actual pedalling speed is measured by a tachometer and the supplied voltage simultaneously is used for the adjustment of the work load independent of this speed. The new equipment can be used both for dynamic and static ergometric investigations with the advantage of rational and exact test procedures and the extended possibilities of application for the use in clinics, sports medicine, applied physiology and research in general.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Trabert, N Tiedt, L Trabert, J Otto. 1980. [Programmable and universally controlled electronic bicycle ergometer].. https://pubmed.ncbi.nlm.nih.gov/7445909/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Set-up verification of cervix cancer patients treated with long treatment fields; implications of a non-rigid bony anatomy.

BACKGROUND AND PURPOSE: For cervix cancer patients, treatment fields may extend up to vertebra L1. In clinical practice, set-up verification is based on measured displacements of the pelvic rim as visible in the caudal part of the treatment fields. The implications of this procedure for the positions of bony structures in the cranial part of the fields were investigated. MATERIALS AND METHODS: Twelve patients had four repeat simulator sessions. Both during treatment simulation (the reference) and the repeat sessions, anterior radiographs were acquired covering the whole treatment field. The films were used to investigate differences between the cranial and the caudal parts of the treatment field in day-to-day bony anatomy displacements. RESULTS: Both in the transversal and the longitudinal directions, these differences were significant (3.5 mm, 1 SD). Indications were found that large differences in the cranio-caudal direction may be correlated with (non-rigid) internal pelvic rim rotations around a lateral axis. In the longitudinal direction, the position of L1 correlated much better with the position of vertebra S1 than with the position of the pelvic rim, which is usually used for set-up verification. CONCLUSIONS: Due to the non-rigid bony anatomy of the studied patients, the usual set-up verification and correction procedure can result in set-up errors of 10 mm and more for structures in the cranial part of the treatment field, even in the case of a perfect set-up of the pelvic rim. Possibly, other patient set-up and immobilization procedures may result in a better day-to-day reproducibility of the 3D bony anatomy shape. (Remaining) Differences in anatomy position changes between the caudal and cranial field ends may be accounted for by using non-uniform clinical target volume-to-planning target volume margins, or by an adapted patient set-up verification and correction protocol.

Electronics, Medical↗

[Optoelectronic plethysmography: a new tool in respiratory medicine].

Opto-electronic plethysmography (OEP) is a new noninvasive technique, recently introduced, which is highly accurate in the measurement of total chest wall volume variations, allowing partitioning of the complex shape of the chest wall into different functional compartments. It can measure breathing patterns and, if combined with pressure measurements, can be used to study statics, dynamics and energetics of the respiratory system. OEP does not require connection to the patient and can be used without a subject-specific calibration. All these features and the results obtained in several studies make the OEP not only a reliable system for basic physiological and pathophysiological research studies, but also an attractive tool to be used in clinics.

Electronics, Medical↗