[Implants in retinal detachment surgery (author's transl)].

Abstract

This paper concerns experience gained by the authors with implants utilized during the past six years at the 1st University Eye Clinic, Vienna, in surgical treatment of 704 cases of rhegmatogenous retinal detachment: in 493 procedures a scleral buckle (silastic sponge in 81%) was applied, in 211 cases an encircling element (a silicon rod 2 mm in diameter in 83%). The subretinal fluid was drained in 52% of the buckling procedures, and in 90% of the encircling procedures. The success rate was 93% in the cases treated by buckling, and 79% following an encircling procedure. Thirty-four cases exhibiting massive periretinal proliferation and three cases with giant ears extending over 180 degrees were treated by retinopexy and indentation of the scleral wall in combination with vitrectomy followed by insufflation of SF6 gas. In 13 of these cases (two of them with giant tears) an anatomical cure was achieved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Freyler, I Scheimbauer. 1980. [Implants in retinal detachment surgery (author's transl)].. https://doi.org/10.1055/s-2008-1057652

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗