B-mode registration: a new procedure for analyzing errors.

Abstract

The theory of a new B-mode registration test procedure is presented along with experimental verification of the detailed theoretical predictions. The new procedure separately tests the B-scan articulated arm calibration and the equipment acoustic velocity calibration. Readily verifiable secondary standards are incorporated into the procedure for self-calibration purposes. The procedure provides a specific and reproducible analysis of angular misregistration errors while maintaining an acceptable level of sensitivity. No coupling gels or oils operator skill is required. A special test has been found which permits the service person to verify that the equipment is capable of attaining proper B-mode registration before beginning the recalibration procedure.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M F Insana, A Goldstein. B-mode registration: a new procedure for analyzing errors.. https://doi.org/10.1118/1.594732

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A transmission electron microscope (TEM) calibration standard sample for all magnification, camera constant, and image/diffraction pattern rotation calibrations.

A calibration sample for transmission electron microscopy (TEM) has been developed that performs the three major instrument calibrations for a transmission electron microscope: the image magnification calibration for measurements of images, the camera constant calibration for indexing diffraction patterns, and the image/diffraction pattern rotation calibration for relating crystal directions to features in the image. This offers an improvement over commercially available calibration standards, where up to five different samples are required to perform these three calibrations. The new calibration sample consists of an electron-transparent cross-sectional TEM sample made from a molecular beam epitaxy (MBE)-grown, single-crystal semiconductor wafer. When the calibration structure is viewed in a TEM, it appears as a series of light and dark layers where the layer thicknesses are very accurately known. The calibrated thickness measurements of these light (silicon) and dark (SiGe alloy) layers are based on careful TEM measurements of the [111] lattice spacing of silicon which is visible on the calibration sample itself, and are supported by X-ray diffraction measurements. Furthermore, the layer thickness variation across the entire silicon wafer has been verified to be less than 1%, allowing all samples prepared from the same wafer to have errors in the given layer thickness values of less than 1%. As the sample is a single crystal of silicon, the calibrations requiring electron diffraction information such as the camera constant calibration and the image/diffraction pattern rotation calibration can also be performed easily and unambiguously. One single calibration sample can therefore be used to provide all three of the major TEM instrument calibrations at all magnifications and all camera lengths.

Calibration

Dosimetric characteristics of a liquid-filled electronic portal imaging device.

PURPOSE: To determine the characteristics of a commercial electronic portal imaging device (EPID), based on a two-dimensional matrix of liquid-filled ionization chambers, for transmission dose measurements during patient treatment. METHODS AND MATERIALS: Electronic portal imaging device measurements were performed in a cobalt-60 beam and two accelerator x-ray beams, and compared with measurements performed with a Farmer-type ionization chamber in air in a miniphantom and in an extended water phantom. RESULTS: The warming up time of the EPID is about 1 h. The long-term stability of the detector is better than 1% under reference conditions for a period of about 3 months. The signal of the ionization chambers follows approximately the square root of the dose rate, although the relation becomes more linear for larger (> 1 Gy/min) dose rates. The signal can be transformed to dose rate with an accuracy of 0.6% (1 SD). The short-term influence of integrated dose on the sensitivity of the ionization chambers is small. The sensitivity increases about 0.5% for all ionization chambers after an absorbed dose of 8 Gy and returns to its original value in less than 5 min after stopping the irradiation. This small increase in sensitivity can be ascribed to the electrode distance of the ionization chambers in commercial EPIDs, which is 0.8 +/- 0.1 mm. The sensitivity increase depends on the electrode distance and is 4% for a 1.4 mm electrode distance. The scattering properties of the EPID ionization chambers were between those of an ionization chamber in a miniphantom and in a water phantom. CONCLUSION: The matrix ionization chamber EPID has characteristics that make it very suitable for dose rate measurements. It is therefore a very promising device for in vivo dosimetry purposes.

Calibration