Fatigue test machine for denture base polymers.

Abstract

A description of a single station fatigue test machine suitable for denture base polymers is given. This machine has been especially designed for dental purposes. A group of representative denture base polymers has been tested, which includes dental poly(methylmethacrylate) of the standard heat polymerized type, autopolymerizing pour type and a heat polymerized rubber graft polymer. These materials were compared and some preliminary results are given. These show that the rubber demonstrated the most satisfactory fatigue life and the pour types were least satisfactory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G D Stafford, T T Lewis. 1980. Fatigue test machine for denture base polymers.. https://doi.org/10.1016/0142-9612(80)90050-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Concept and development of a measuring system for in vivo recording of orthodontically applied forces and torques in the multiband technique. Part I.

The cause of tooth movement with a multiband or multibracket appliance is the force system in the bracket, which is generated by an archwire and transmitted by a bracket to the respective tooth. Continuous arch wires are, from the biomechanical point of view, a statically multiply undetermined system. Quantitative determination of the forces and torques acting at the individual teeth, and thus observance of a non-critical level of applied forces, is therefore extremely problematic in practice, the force is applied by the orthodontist more or less "intuitively" on the basis of recommendations evolved in theory and in vitro. The measuring technique presented in this paper is designed to permit these force systems to be recorded in vivo for the first time, allowing account to be taken of the individual situation "tooth-periodontium-bone". Evolvement of an appropriate measuring principle was followed by development of the individual components of the measuring system. The results of the subsequent initial in vitro test series offer the prospect of successful clinical application.

Dental Stress Analysis

Frictional resistances in stainless steel bracket-wire combinations with effects of vertical deflections.

This research evaluated the effects of different bracket-wire combinations and second-order deflections on kinetic friction. Thirteen different brackets, six with 0.018 x 0.025 inch slots and seven with 0.022 x 0.028-inch slots were evaluated with six different sizes and shapes of stainless steel orthodontic wire, i.e., 0.016, 0.016 x 0.022, 0.017 x 0.025, 0.018, 0.018 x 0.025 and 0.019 x 0.026 inch for four second order deflections of 0.00, 0.25, 0.50, and 0.75 mm. The wires were ligated into the brackets with elastomeric modules. Bracket movement was implemented by means of an Instron universal testing instrument (RMO, Denver, Colo.), and frictional forces were measured by a tension load cell and recorded on an X-Y recorder (Hewlett-Packard, Anaheim, Calif.). Second-order deflection was created by a specially designed and machined testing apparatus that allowed two alternate pairs of the four total brackets to be offset in increments of 0.25 mm. The kinetic frictional force increased for every bracket-wire combination tested as the second-order deflection increased. Friction also increased with an increase in wire size, whereas rectangular wires produced greater friction than round wires. Bracket designs that limited the force of ligation on the wire generated less friction at low second-order deflections (0.00 and 0.25 mm).

Dental Stress Analysis

Frictional resistance between orthodontic brackets and archwires in the buccal segments.

Orthodontic sliding mechanics using preadjusted brackets is a popular approach for achieving incisor retraction. A distally directed force slides the archwire through brackets and tubes in the buccal segments. Friction in the buccal segments contributes resistance to the force required to achieve tooth movement, and techniques to reduce friction reduce the potential for anchorage loss. This in vitro study used an Instron testing machine to assess frictional forces for three types of 0.022 x 0.028 inch brackets: preadjusted stainless steel premolar brackets (Standard Straight Wire, "A" Company, Inc, San Diego, Calif), Activa brackets ("A" Company Inc, San Diego, Calif), and Speed brackets (Strite Industries Ltd), combined with five wire sizes (0.018, 0.020, 0.016 x 0.022, 0.018 x 0.025 and 0.019 x 0.025 inch). A model with one attached molar bracket and one or two premolar brackets simulated the buccal segments. Activa brackets produced the least friction for all wires tested. Speed brackets with round wires showed little frictional force while rectangular wires gave rise to higher forces, at levels similar to those recorded with two Standard Straight Wire brackets. Static friction for round wires in standard brackets was found to be 178-275 gm-force. The ratio of static to dynamic friction was remarkably consistent in all tests. Different methods of ligation were compared for their effect on static friction. Ligation with loosely placed ligatures or stretched modules reduced frictional forces in Standard Straight Wire brackets, the reduction being greatest for round archwires. Frictional forces recorded from archwires secured with elastomeric modules showed a steady reduction over a 3-week period, depending on how long the module had been in position on the bracket.

Dental Stress Analysis