PubMed HealthSearch

PubMed · 7562721

A fixed anastomotic coupling device.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Oguchi, K Fukuta. 1995. A fixed anastomotic coupling device.. https://doi.org/10.1055/s-2007-1006545

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel one-shot anastomotic stapler prototype for coronary bypass grafting on the beating heart: feasibility in the pig.

OBJECTIVE: The nonpenetrating, arcuate-legged clip has proved its ability to provide a high-quality microvascular anastomosis. This study assessed the feasibility of constructing a coronary end-to-side anastomosis on the beating heart with a novel mechanical, sutureless anastomotic device that applies 12 circumferential clips simultaneously. METHODS: In 14 consecutive pigs (70-90 kg), the left internal thoracic artery (diameter, 3 mm) was grafted to the left anterior descending coronary artery (diameter, 3 mm) by means of a one-shot anastomotic stapler prototype. Endothelial denudation, medial necrosis, and intimal hyperplasia were analyzed quantitatively and compared with those seen in conventionally sutured anastomoses (n = 4). RESULTS: In 8 of 14 anastomoses, the one-shot anastomotic stapler successfully applied all 12 clips circumferentially across the everted arteriotomy edges. In the remaining, either 1 (n = 4) or 3 and 4 adjoining malaligned clips had to be replaced manually with a single-clip applicator. Coronary occlusion was limited to approximately 3 minutes. At follow-up, all anastomoses were patent angiographically. At 2 days, in 2 of 7 cases, a local coronary dissection was observed, and there was a considerable loss of endothelial cells and medial damage. At 28 days, however, minimal intimal hyperplasia was seen at the anastomotic lining, although more pronounced when compared with conventionally sutured anastomoses. CONCLUSIONS: The one-shot anastomotic stapler prototype enabled short-occlusive (3 minutes), sutureless end-to-side grafting on the beating porcine heart. In spite of early endothelial and medial damage and 2 local dissections, all anastomoses remained patent with minimal intimal hyperplasia at 4 weeks.

Anastomosis, Surgical

Late effects of intraoperative radiation therapy in anastomotic rat colon.

PURPOSE: to determine whether intraoperative radiotherapy causes long-term negative effects on the healing of colonic anastomoses in the rat. METHODS AND MATERIALS: 175 rats were divided into seven equal groups. One group served as sham-irradiated control group. In the others, following a colonic resection, 1 or 2 cm of the distal bowel limb was irradiated with a single dose of 10, 15, or 20 Gy (groups 10/1, 15/1, 20/1, 10/2, 15/2, and 20/2, respectively). Subsequently, an anastomosis was constructed. The animals were killed after 6 (n = 10 in each group) or 12 (n = 15) months. The abdomen was inspected for abnormalities and the colonic diameter was measured. The anastomotic segment was analyzed biochemically (hydroxyproline) and histologically. RESULTS: During the experimental period, 1 rat (group 15/1) died because of anastomotic leakage and 3 others died from unknown causes. There was no difference in colonic diameter between groups. Altogether 17 rats developed an adenocarcinoma in the irradiated area: 11 of these had received a dose of 20 Gy. Histological observation indicated that fibrosis was present only in a limited number of animals, mostly after irradiation with a dose of 15 or 20 Gy. All anastomoses were functional and showed normal histology. The hydroxyproline content of the anastomotic segment was increased--with respect to the control group--only in the 20/2 group after 6 months. After 12 months, the hydroxyproline concentration in the (irradiated) segment distal to the anastomosis proper was higher in the 10/1 and 15/1 groups than in the control group. Otherwise, there were no differences between groups. CONCLUSION: Intraoperative irradiation with a single dose of 10-20 Gy, delivered to the distal limb used for anastomotic construction, does not appear to constitute a threat to anastomotic integrity. Dose-related changes included formation of adenocarcinomas and fibrosis, but function and histology of the anastomosis proper remained unaffected.

Anastomosis, Surgical