PubMed HealthSearch

PubMed · 7564138

[Computer program for improved diagnostic coding in ophthalmology based on the expanded ICD 10].

Abstract

BACKGROUND: The coding of ophthalmological diagnoses is a long-standing problem that has recently been highlighted by the planned introduction of ICD 10. METHODS: Using an alphanumerical classification system for the first time, ICD 10 offers the space needed for necessary expansion without leading once again to dislocations in the numbering system. The FoxPro 2.5 database system was used to create a program based on an expanded ICD 10 that can be applied from DOS and Windows. RESULTS: ICD 10 was expanded by the addition of a numerical fifth digit, thus increasing the number of classifiable ophthalmological disorders by a factor of 4.2 from 390 to 1635. The new program greatly facilitates the handling of this substantial amount of data. CONCLUSIONS: The enhanced diagnosis coding achieved with the expanded ICD 10 permits nosologically exact statistics to be kept for use as a basis for further scientific work.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Kuchenbecker, O Ehrt, R Guthoff. 1995. [Computer program for improved diagnostic coding in ophthalmology based on the expanded ICD 10].. https://doi.org/10.1055/s-2008-1035348

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A computer-controlled conformal radiotherapy system. IV: Electronic chart.

PURPOSE: The design and implementation of a system for electronically tracking relevant plan, prescription, and treatment data for computer-controlled conformal radiation therapy is described. METHODS AND MATERIALS: The electronic charting system is implemented on a computer cluster coupled by high-speed networks to computer-controlled therapy machines. A methodical approach to the specification and design of an integrated solution has been used in developing the system. The electronic chart system is designed to allow identification and access of patient-specific data including treatment-planning data, treatment prescription information, and charting of doses. An in-house developed database system is used to provide an integrated approach to the database requirements of the design. A hierarchy of databases is used for both centralization and distribution of the treatment data for specific treatment machines. RESULTS: The basic electronic database system has been implemented and has been in use since July 1993. The system has been used to download and manage treatment data on all patients treated on our first fully computer-controlled treatment machine. To date, electronic dose charting functions have not been fully implemented clinically, requiring the continued use of paper charting for dose tracking. CONCLUSIONS: The routine clinical application of complex computer-controlled conformal treatment procedures requires the management of large quantities of information for describing and tracking treatments. An integrated and comprehensive approach to this problem has led to a full electronic chart for conformal radiation therapy treatments.

Data Display