Does the time course of bubble evolution explain decompression sickness risk?

Abstract

A probabilistic model of decompression sickness (DCS) risk based on linear-exponential (LE) kinetics has given the best fit of the human air and nitrox DCS database. To test the hypothesis that its success may be due to the formation of a gas phase during decompression, we developed a physiologically based bubble evolution model using a numerical solution of a partial differential equation system. Because of the computational intensity of this method, it could not be used to fully explore our hypothesis. Consequently, we compared the solution with that of a computationally simpler approximation that was previously published by Van Liew and found the two approaches gave similar results. Using the simpler model, assuming bubble densities of 1 and 1,000 bubbles/cm3, we found a tissue time constant of at least 80 min (equivalent to perfusion of 1/80 ml.g-1.min-1) was required to achieve a delay in bubble dissolution comparable to the prolonged risk of DCS predicted by the LE model. We suggest that the persistence of single bubbles in a uniformly perfused homogeneous tissue alone is unlikely to explain persistent DCS risk.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Ball, J Himm, L D Homer, E D Thalmann. 1995. Does the time course of bubble evolution explain decompression sickness risk?. https://pubmed.ncbi.nlm.nih.gov/7580767/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse.

BACKGROUND: A complete understanding of fluid mechanics in Fontan physiology includes knowledge of the caval contributions to right (RPA) and left (LPA) pulmonary arterial blood flow, total systemic venous return, and relative blood flow to each lung. METHODS AND RESULTS: Ten Fontan patients underwent cine MRI. Three cine scans of the pulmonary arteries were performed: (1) no presaturation pulse, (2) a presaturation pulse labeling inferior vena cava (IVC) blood (signal void), and (3) a presaturation pulse labeling superior vena cava (SVC) blood. The relative signal decrease is proportional to the amount of blood originating from the labeled vena cava. This method was validated in a phantom. Whereas 60+/-6% of SVC blood flowed into the RPA, 67+/-12% of IVC blood flowed toward the LPA. Of the blood in the LPA and RPA, 48+/-14% and 31+/-17%, respectively, came from the IVC. IVC blood contributed 40+/-16% to total systemic venous return. The distributions of blood to each lung were nearly equal (RPA/LPA blood=0.94+/-11). CONCLUSIONS: In Fontan patients with total cavopulmonary connection, SVC blood is directed toward the RPA and IVC blood is directed toward the LPA. Although the right lung volume is larger than the left, an equal amount of blood flow went to both lungs. LPA blood is composed of equal amounts of IVC and SVC blood because IVC contribution to total systemic venous return is smaller than that of the SVC. This technique and these findings can help to evaluate design changes of the systemic venous pathway to improve Fontan hemodynamics.

Blood Flow Velocity

Voxel sensitivity function description of flow-induced signal loss in MR imaging: implications for black-blood MR angiography with turbo spin-echo sequences.

The conditions in which the image intensity of vessels transporting laminar flow is attenuated in black-blood MR angiography (BB-MRA) with turbo spin-echo (TSE) and conventional spin-echo (CSE) pulse sequences are investigated experimentally with a flow phantom, studied theoretically by means of a Bloch equation-voxel sensitivity function (VSF) formalism, and computer modeled. The experiments studied the effects of: a) flow velocity, b) imaging axes orientation relative to the flow direction, and c) phase encoding order of the TSE train. The formulated Bloch equation-VSF theory describes flow effects in two-dimensional (2D)- and 3D-Fourier transform magnetic resonance imaging. In this theoretical framework, the main attenuation mechanism instrumental to BB-MRA, i.e., transverse magnetization dephasing caused by flow in the presence of the imaging gradients, is described in terms of flow-induced distortions of the individual voxel sensitivity functions. The computer simulations predict that the intraluminal homogeneity and extent of flow-induced image intensity attenuation increase as a function of decreasing vessel diameter, in support of the superior image quality achieved with TSE-based BB-MRA in the brain.

Blood Flow Velocity

Using flow relaxography to elucidate flow relaxivity.

We have investigated the theoretical and experimental linear dependence of the reciprocal of the apparent longitudinal relaxation time [(T*1)-1] of the NMR signal from spins in a flowing fluid on the volume flow rate, Fv, the so-called inflow effect. We refer to the coefficient of this dependence as the longitudinal flow relaxivity, r1F. A very simple model predicts that, under a range of conditions pertinent to modern flow studies and perfusion imaging experiments, r1F is controlled by the volume of the fluid in which the magnetization is perturbed by pulsed RF inversion or saturation, not the detection volume, and that it can be approximated as the reciprocal of half of the inversion volume. Phantom sample experiments, using a new, quantitative approach that we call flow relaxography, confirm the general predictions of this simple model. There are two intriguing implications of these findings for general NMR flow studies as well as for medical applications. It should be possible to vary the value of r1F by simply (noninvasively) adjusting the inversion slice thickness, and thus measure the value of (blood 1H2O, for example) Fv in a vessel without changing Fv, from the resultant varying T*1 values. Also, it should be possible to extrapolate to the intrinsic T1 value of the fluid signal (as if it were stationary), without altering or stopping the flow. Again, these are quite successful in phantom sample studies. Imaging versions of the flow relaxographic experiments are also possible. The twin goals of flow studies in medical MRI are the quantitative discrimination of the signals from flowing and nonflowing spins, and the accurate measurement of the flow rate of the former.

Blood Flow Velocity