PubMed Health⌕ Search

PubMed · 7580914

Multiple fluorescence-based PCR-SSCP analysis with postlabeling.

Abstract

Multiple fluorescence-based PCR single-strand conformation polymorphism (MF-PCR-SSCP) with postlabeling was developed. The target sequence was amplified by PCR using unlabeled primers. Free dNTPs were removed from the amplified products by ethanol precipitation. The dNTPs at the 3' ends of the amplified DNA fragments were exchanged with fluorescent dUTPs or ddNTPs using Klenow fragment of DNA polymerase I. The DNA fragments labeled with fluorescent dUTPs or ddNTPs were heat denatured and applied to a nondenaturing polyacrylamide gel set on an automated DNA sequencer with a gel temperature-controlling system. The image data were analyzed by the computer program Genescan 672. By use of MF-PCR-SSCP with postlabeling, seven different single base mutations of the human K-ras oncogene were detected even under one electrophoresis condition.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Iwahana, K Adzuma, Y Takahashi, R Katashima, K Yoshimoto, M Itakura. 1995. Multiple fluorescence-based PCR-SSCP analysis with postlabeling.. https://doi.org/10.1101/gr.4.5.275

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

RHIZOSCAN: A semiautomatic image processing system for characterization of the morphology and secondary metabolite concentration in hairy root cultures.

We describe the application of the newly developed RHIZOSCAN software for accurate morphological analysis and determination of overall and local secondary metabolite concentrations in two clones of Beta vulgaris throughout the growth period. Local secondary metabolite concentrations may be determined at any point in the root, and pigment gradients in each lateral root can be followed during culture and saved to the computer. Throughout the entire analysis process, an image appears in a graphical result window on the screen, which enables visual evaluation of the numerical output at each stage of the analysis. Biosynthetic data on concentrations obtained by image analysis were validated by spectrophotometric analysis. The importance of determining appropriate scanning and analysis conditions (scanning resolution, background color, threshold value, segmentation plane in the hue-saturation-intensity color system and pruning length) for obtaining accurate morphological measurements is examined and the means of fixing these parameters is described. Our results show that, using RHIZOSCAN, detailed and accurate information on root architecture and secondary metabolite concentrations can be obtained in a short time.

Automation↗

Automated one-step DNA sequencing based on nanoliter reaction volumes and capillary electrophoresis.

An integrated system with a nano-reactor for cycle-sequencing reaction coupled to on-line purification and capillary gel electrophoresis has been demonstrated. Fifty nanoliters of reagent solution, which includes dye-labeled terminators, polymerase, BSA and template, was aspirated and mixed with the template inside the nano-reactor followed by cycle-sequencing reaction. The reaction products were then purified by a size-exclusion chromatographic column operated at 50 degrees C followed by room temperature on-line injection of the DNA fragments into a capillary for gel electrophoresis. Over 450 bases of DNA can be separated and identified. As little as 25 nl reagent solution can be used for the cycle-sequencing reaction with a slightly shorter read length. Significant savings on reagent cost is achieved because the remaining stock solution can be reused without contamination. The steps of cycle sequencing, on-line purification, injection, DNA separation, capillary regeneration, gel-filling and fluidic manipulation were performed with complete automation. This system can be readily multiplexed for high-throughput DNA sequencing or PCR analysis directly from templates or even biological materials.

Automation↗

Automating solid-phase extraction: current aspects and future prospects.

This paper reviews current trends and techniques in automated solid-phase extraction. The area has shown a dramatic growth the number of manuscripts published over the last 10 years, including applications in environmental science, food science, clinical chemistry, pharmaceutical bioanalysis, forensics, analytical biochemistry and organic synthesis. This dramatic increase of more that 100% per year can be attributed to the commercial availability of higher throughput 96-well workstations and extraction plates that allow numerous samples to be processed simultaneously. These so-called parallel-processing workstations represent the highest throughput systems currently available. The advantages and limitations of other types of systems, including discrete column systems and on-line solid-phase extraction are also discussed. Discussions of how automated solid-phase extractions can be developed, generic approaches to automated solid-phase extraction, and three noteworthy examples of automated extractions are given. The last part of the review suggests possible near- and long-term directions of automated solid-phase extraction.

Automation↗