PubMed HealthSearch

PubMed · 7596607

Plasti-pore implants in middle ear surgery.

Abstract

Plasti-pore, a high-density polyethylene sponge, was one of the earliest biocompatible materials developed specifically for implantation in the middle ear. It is one of the most nonreactive materials known when tested in simulated biochemical exposure to pseudoextracellular fluid. The two basic prosthetic designs are the total ossicular replacement prosthesis and the partial ossicular replacement prosthesis. Plasti-pore implants have now been used for 20 years and are widely accepted by otologic surgeons. The basic properties of the material, implant design, and surgical techniques involved using these prostheses are reviewed in this article.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J R Emmett. 1995. Plasti-pore implants in middle ear surgery.. https://pubmed.ncbi.nlm.nih.gov/7596607/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Epitympanic diaphragm in the new-born.

A series of 80 temporal bones included four specimens from infection-free new-born children. The microdissections showed that the epitympanic diaphragm in the new-born consists, in addition to the position fixed ligamental folds and ossicles, of only two position changing duplicate folds. These were the lateral incudomalleal fold, separating the upper and lower lateral attics, and the tensor fold, separating the anterior epitympanum from the supratubal recess. All other duplicate folds present during the fetal development had disappeared, a finding in accordance with the study on fetuses by Hammar in 1902 and with our own microdissection findings in normal adult temporal bones. Folds in other locations, even if until lately considered as participants of a normal epitympanic diaphragm, are of inflammatory origin.

Ear Ossicles

[A micromanipulator for intraoperative vibratory hearing assessment with an implantable hearing aid transducer].

First concepts of implantable hearing aids to be coupled to the ossicular chain are available for patients with combined or sensorineural hearing loss (SNHL). To ensure that hearing can be improved intraoperative coupling of a test transducer to the ossicular chain is mandatory for allowing surgical anatomy to be checked and vibratory hearing tests to be performed. To achieve this, the test transducer has to be held and positioned securely in situ for some minutes, avoiding risks for middle or inner ear structures. This is not possible using conventional surgical instruments. Thus, a micromanipulator to hold the test transducer during intraoperative hearing tests was developed. This surgical device allows the surgeon safe, risk-free, and controlled coupling of the test transducer to the ossicular chain with one axial and three rotational degrees of freedom. With the aid of a conventional ear retractor (2x2 prongs), the manipulator is fixed at the patient's ear. In conjunction with a piezoelectric test transducer, the manipulator was used in nine patients during local anesthesia. The test transducer is part of an electronic hearing implant (Tübingen implant) specifically designed for SNHL that may be coupled to a middle ear ossicle or the perilymph of the cochlea. The micromanipulator was easy to handle. It allowed accurate positioning of the test transducer in the ear and the desired coupling of the transducer's probe tip to the ossicular chain during auditory tests. According to the principles of integrated safety, the intraoperative risk of ossicular or inner ear injuries caused, for instance, by the patient's head movement is minimized. The design of the manipulator system is universal, also allowing its use for other electronic hearing implants or minimal invasive surgery after minor modifications.

Ear Ossicles

Incus and stapes footplate simulator.

Prosthesis placement in stapes surgery is difficult to master. Although temporal bone dissection is an important adjunct to operative experience and anatomic knowledge when training residents to perform this procedure, the high cost and scarcity of temporal bones available for teaching purposes limit their convenience as teaching tools. Therefore, to augment training of residents, the authors developed an inexpensive, easily constructed middle ear simulator made from a disposable drinking cup, toothpicks, and a tongue depressor. The device is used with a microscope and ear instruments to manipulate, place, and crimp stapes prostheses. Improved surgical skills can lead to better surgical results, and this middle ear simulator can help to improve otologic surgical skills by giving residents the opportunity to practice techniques necessary to master stapes surgery.

Ear Ossicles