PubMed HealthSearch

PubMed · 7600417

[Mandibular permanent cuspids with two roots].

Abstract

When one reviews the literature, it is quite apparent that there seems to be many assumptions relative to the number of roots found in mandibular permanent canines. After having examined 806 specimens, the author of this article found that 95 per cent of mandibular canines had one root and five per cent had two roots.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Ouellet. 1995. [Mandibular permanent cuspids with two roots].. https://pubmed.ncbi.nlm.nih.gov/7600417/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Frictional forces when rectangular guiding arches with varying edge bevel are employed.

In orthodontic treatment employing arch guided tooth movement, rectangular wires are usually used to achieve three-dimensional controlled tooth movement. In the intention to optimize sliding mechanics and to improve the comfort of patients, edge beveled rectangular orthodontic wires are offered by different manufacturers. The objective of the study presented was to investigate the influence of differing but defined wire roundings on sliding mechanics of canine retraction. Employing the 0.018" slot system, 0.016" x 0.022" standard steel wires (Remaloy and Remanium, Dentaurum Comp.) were tested. Force loss due to friction during canine retraction was determined using the Orthodontic Measurement and Simulation System (OMSS). In the arch guided distalization of canines, the average loss of force caused by friction was determined to be approximately 50%. Comparing wires with different edge bevel, the rounded wire in contrast to the wire with sharpest edge configuration results in a reduction of friction. Even a moderate wire rounding of the 0.016" x 0.022" steel wire results in about 10% reduction in frictional losses. However, dynamic analysis of tooth movement with the OMSS shows that there is no further improvement of sliding mechanics using wires with edge bevel exceeding the standard rounding of rectangular wires. In contrast, a strong edge bevel may result in a considerable loss of leveling.

Cuspid

The effect of second-order couple on the application of torque.

Complex combinations of linear forces, moments, and couples are developed by the arch wire during orthodontic treatment. For instance, application of torque to a canine during distal driving may create force interactions if the tooth tips distally toward the extraction site. This investigation studied the effect of second-order couples and bracket angulations on the application of torque to a single tooth. By using a test apparatus to simulate application of torque to a single tooth, 0.016 x 0.022 inch stainless steel wires were tested in longitudinal torsion simultaneous to fixed amounts of second-order couples or fixed degrees of second-order bracket angulation. Application of a second-order couple through a bracket to a longitudinally twisted arch wire produces a third-order couple, since the bracket slot walls exert forces on the wire, tending to detwist it. This third-order couple will usually be small as the distance between the two couple members is short. Nevertheless, it may have a restraining effect on the third-order wire-bracket interaction. The results show that application of second-order couples or bracket angulations lead to an increase in exerted torque for angles of twist below 22 degrees. Because of torsional play, a wire twisted 18 degrees in a 0.018-inch bracket slot did not exert any torque unless it was subjected to a second-order couple. Thus, in an in vivo situation where forces interact, the actual torsional play may be substantially less than predicted from theoretical models only regarding third-order mechanics. The restraining effect of second-order couples tapered when the torque created by longitudinal twisting became much larger than the torque exerted by the second-order couple. Second-order couples of biologically acceptable magnitudes had little effect on the level of torque after the third-order clearance had been eliminated.

Cuspid

The external and internal anatomy of human mandibular canine teeth with two roots.

This study investigated the internal anatomy of 65 human mandibular canines with two well-defined roots. The teeth were decalcified and injected with gelatin coloured with india ink. Diaphanization was carried out using clear resin to allow permanent preservation. It was found that all mandibular canines with two roots had two root canals. Lateral canals were found in 68.9% of teeth and 19.7% had lateral canals at the bifurcation. The results of the external measurements (cusp tip to root apex) showed that the average buccal root length was 23.0 mm and the average lingual root length was 22.7 mm. The maximum and minimum buccal lengths were 26.7 mm and 17.9 mm respectively and the maximum and minimum lingual lengths were 27.2 mm and 17.1 mm respectively. The buccal root was the larger of the two in 47.7% of teeth and 43.1% had roots of equal size. The lingual root was larger than the buccal root in 9.2% of cases. Clinicians should be aware of the anatomical variation that exists for mandibular canines.

Cuspid