Technical note: computed tomography imaging with a radiotherapy simulator.

Abstract

An inexpensive system for obtaining cross-sectional information and accurate body outlines of patients destined for radiotherapy, using a radiotherapy simulator without any major modifications, has been investigated. The image intensifier of the simulator was moved laterally and a narrow fan beam of X-rays passed through the phantom onto the intensifier. Several television (TV) lines of the video signal from the TV camera were digitized by a frame grabber and stored for reconstruction. Multiple projections were acquired by rotating the gantry of the simulator. The field of view was enlarged by increasing the offset distance of the image intensifier and taking two sets of projections. Reconstruction was carried out by using the convolution and back-projection method. The gradient between pixel values in the reconstructed images was used to detect the outlines of structures in the images. The accuracy of outline detection was evaluated with images of a Rando phantom. The outlines of the images were compared with the actual outlines of the phantom. The spatial resolution of the simulator computed tomography (CT) was measured to be 4.05 mm. Large inhomogeneities could be clearly seen. The average difference between the measured and the actual outlines was 3.0 mm with a maximum difference of 10.0 mm at sharp curves in the outline. The simulator CT provides an inexpensive, alternative method of obtaining body outlines and does not require any modifications to the simulator. Data acquisition, processing and display can be performed on a personal computer with image processing facilities.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J S Engelbrecht, J Duvenage, C A Willemse, M G Lötter, L Goedhals. 1995. Technical note: computed tomography imaging with a radiotherapy simulator.. https://doi.org/10.1259/0007-1285-68-810-649

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Dosage measurements in spiral CT examinations of the head and neck region].

PURPOSE: In view of the increasing frequency of computed tomographic examinations the organ doses of the thyroid gland and the eye lenses in spiral CT examinations of the head and neck should be determined. MATERIAL AND METHODS: Standard CT-examinations of the neck, the paranasal sinuses in axial and coronal sections, and the mandibula were simulated by help of an Alderson-Rando phantom. Dose measurements were performed as well in 28 patients. The examinations were carried out in spiral mode ("Somatom AR.SP", "Picker PQ 2000", and "Toshiba Xpress SX") and conventional single slice technique ("Somatom Plus"). Three LiF-TLD were placed on each eyelid and three on the thyroid. RESULTS: With direct exposure to the x-ray-beam the organ doses did not exceed 64 mGy. When exposed by scatter radiation only, doses may be reduced by a factor of up to 10. The measurements in 28 patients showed similar results. CONCLUSIONS: The organ doses in spiral CT correspond with data known from conventional CT.

Head

A simple method for investigating the effects of non-uniformity of radiofrequency transmission and radiofrequency reception in MRI.

Inhomogeneity of the transmitted or received B1 field leads to intensity variations in MR images and spatial dependence in apparent concentration in MR spectra. We describe a simple method for investigating such variations. The transmitted B1 field can be measured both in vivo and in vitro which allows investigation of sample dependent effects that can not be measured on phantoms. For homogeneous regions the method also allows the received B1 field to be measured both in vivo and in vitro. Our method uses only a standard spin echo pulse sequence and simple region of interest analysis and should be implementable on any commercial scanner. The method is demonstrated using a variety of transmission and reception radiofrequency coils both in vivo and in vitro.

Head