PubMed Health⌕ Search

PubMed · 7648834

Validation of a modified Kirby-Bauer disk diffusion method for metronidazole susceptibility testing of Helicobacter pylori.

Abstract

Triple antimicrobial therapy that includes metronidazole has been recommended as a first-line therapy for Helicobacter pylori because it has the highest eradication rates. However, resistance in H. pylori to metronidazole has been reported worldwide and its presence may reduce the efficacy of triple therapy. Various methods for testing H. pylori against metronidazole have been used including agar dilution, disk diffusion and the Etest but there has been little standardization of methods. One hundred isolates of H. pylori from different patients were tested for susceptibility to metronidazole by agar dilution, Etest and disk diffusion (5 micrograms disk). The agar dilution results confirmed the MIC susceptibility breakpoint to be < or = 8 micrograms/ml. Using this breakpoint there was close agreement (98%) between Etest and agar dilution results. For susceptible strains, MICs by E-test were generally one twofold dilution lower. Using the error-rate bounded method, agreement between disk diffusion zone diameter and MIC was 98% for agar dilution with breakpoints of > or = 12 mm and < or = 8 micrograms/ml and 100% for Etest with breakpoints of > or = 12 mm and < or = 8 micrograms/ml. The Etest discriminated better than agar dilution between susceptible and resistant strains and was simple to perform. The disk diffusion test is a reliable and cheaper alternative to the Etest with susceptibility being a zone diameter > or = 12 mm with a 5 micrograms disk. The prevalence of metronidazole resistance in this study was 40% by Etest.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P D Midolo, J Turnidge, J R Lambert, J M Bell. 1995. Validation of a modified Kirby-Bauer disk diffusion method for metronidazole susceptibility testing of Helicobacter pylori.. https://doi.org/10.1016/0732-8893(95)00066-j

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of surface treatment on diffusion and domain formation in supported lipid bilayers.

Supported lipid bilayers are widely used as model systems due to their robustness. Due to the solid support, the properties of supported lipid bilayers are different from those of freestanding bilayers. In this article, we examine whether different surface treatments affect the properties of supported lipid bilayers. It will be shown that depending on the treatment method, the diffusion of the lipids can be adjusted approximately threefold without altering the composition. Additionally, as the bilayer-support interaction decreases, it becomes easier to form coexisting liquid-ordered and liquid-disordered domains. The physical/chemical alterations that result from the different treatment methods will be discussed.

Diffusion↗

An early example of evidence-based medicine: hypoxemia due to nitrous oxide.

Diffusion anoxia. By Bernard Raymond Fink. Anesthesiology 1955; 16:511-14. In 1955, Dr. Bernard Raymond Fink published his findings that described the mechanism by which hypoxemia occurred when nitrous oxide-oxygen anesthesia was discontinued and room air breathing commenced. Using an ear oximeter and brachial artery blood gases, he measured oxygen saturation in eight healthy patients who had received 75% nitrous oxide-25% oxygen for gynecologic surgery. He showed that oxygen saturation decreased from 5% to 10% and often reached a value below 90% when the patient began room air breathing after the nitrous oxide-oxygen was discontinued. The effect was seen over a 10-min period. He concluded that "anoxia arises because the outward diffusion of nitrous oxide lowers the alveolar partial pressure of oxygen." This phenomenon can become a causative factor of cardiac arrest in patients with impaired pulmonary or cardiac reserves.

Diffusion↗