A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator.

Abstract

A mathematical model is derived for digitally controlled linear accelerators to deliver a desired photon intensity distribution by combining collimator motion and machine dose rate variations. It shows that, at any instant, the quotient of the machine dose rate and the speed of collimator motion is proportional to the gradient of the desired in-air photon fluence distribution. The model is applicable for both independently controlled collimator jaws and multileaf collimators and can be implemented by controlling different parameters to accommodate linear accelerators from different manufactures. For independent jaws, each pair of jaws creates photon fluence variations along the direction of the jaw movement. For multileaf collimators, where each leaf is independently controlled, any two-dimensional (2D) photon fluence distribution can be delivered. The model has been implemented for wedged isodose distributions using independent jaws, and 2D intensity modulation using a multileaf collimator. One-dimensional (1D) wedged isodose distributions are created by moving an independent jaw at constant speed while varying machine dose rate. 2D intensity modulation has been implemented using a 'dynamic stepping' scheme, which controls the leaf progression during irradiation at constant machine dose rate. With this automated delivery scheme, the beam delivery time for dynamic intensity modulation, which depends on the complexity of the desired intensity distribution, approaches that of conventional beam modifiers. This paper shows the derivation of the model, its application, and our delivery scheme. Examples of 1D dynamic wedges and 2D intensity modulations will be given to illustrate the versatility of the model, the simplicity of its application, and the efficiency of beam delivery. These features make this approach practical for delivering conformal therapy treatments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C X Yu, M J Symons, M N Du, A A Martinez, J W Wong. 1995. A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator.. https://doi.org/10.1088/0031-9155%2F40%2F5%2F005

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

New high-DQE imaging plate scanner using the reflected readout laser signal for noise corrections.

Imaging Plates (IPs) are in principle ideal electron detectors combining a large active layer area with a high sensitivity, linear dynamic range detection over 5 orders of magnitude. A moderate resolution and a decreasing detection quantum efficiency (DQE) for higher electron doses limit their use so far. The decrease of the DQE results from linear noise contributed by readout laser instabilities and inhomogeneities of the IP active layer. Here we present data on a new IP drum scanner prototype. This scanner combines twin channel amplification electronics with a new type of readout laser which allows a smaller readout focus and increased stability. The current nominal pixel size is 25 microm, and the measured modulation transfer function (MTF) indicates that further reduction of the scanning step size down to pixel sizes in the range of 12-15 microm should be possible. A unique feature of the new scanner is the simultaneous recording of the reflected readout laser light. The reflected light signal can be used for a posteriori alignment of repeated scans of one individual IP and for a correction of one part of the high spatial frequency noise contribution (reflected light correction). The posteriori alignment now allows an easy conventional gain normalization of the luminescence signal without using special markers on the IP. Both corrections lead to an increase of the DQE for high electron doses.

Biophysical Phenomena↗

Evaluation of scanners and CCD cameras for high-resolution TEM of protein crystals and single particles.

The modulation transfer function (MTF) and the geometric errors of two flatbed scanners, a slow-scan CCD (SSC) camera and film, have been measured and compared. The geometric errors of the SSC camera and film have been measured using diffraction spots from a lipid crystal. The SSC camera was shown to have the smallest geometric errors while film had the best MTF. Even though film had the best MTF, this is significantly reduced when scanning the film, so that the MTF of the film and scanner combined are comparable to the MTF of the SSC camera.

Biophysical Phenomena↗

Exit wave reconstructions using through focus series of HREM images.

The through focus exit wave reconstruction technique uses a series of high resolution electron microscopy images to reconstruct the complex electron wavefunction at the exit plane of the specimen. The feasibility of the through focus exit wave reconstruction method and its most important limitations are discussed. It is shown that-provided all aberrations of the microscope are well corrected for-a large improvement in the interpretability of the information can be obtained.

Biophysical Phenomena↗