PubMed Health⌕ Search

PubMed · 7654808

Oxygen saturation post-gastroscopy and post-colonoscopy.

Abstract

A standard of care for providing pulse oximetry monitoring for patients receiving conscious sedation during and after endoscopy has not been established. This study sought to clarify whether desaturation occurs after gastroscopy and colonoscopy and what characteristics are predictive of desaturation that does occur. The convenience sample consisted of 475 adult participants receiving meperidine and/or midazolam in a hospital-based outpatient setting. A baseline oxygen saturation level was obtained before the procedure. Assessment of the oxygen saturation continued in the recovery room for 1 hour, with readings recorded every 10 minutes. A saturation of 90% or less was used as the indicator to resume oxygen therapy. Data revealed that oxygen desaturation in the recovery phase is influenced by the preprocedure baseline oxygen saturation level, smoking history, and age. The incidence of oxygen desaturation was 24% in the recovery phase, with the majority of decreases occurring within the first 10 minutes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Poser, S Ladik. Oxygen saturation post-gastroscopy and post-colonoscopy.. https://doi.org/10.1097/00001610-199507000-00003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative Efficacy of Different AI Systems for Polyp Detection by Size During Colonoscopy: Systematic Review and Network Meta-Analysis.

BACKGROUND: Colorectal cancer remains a leading cause of death despite being largely preventable through polypectomy. AI systems designed to enhance polyp detection during colonoscopy have shown promise, but the extent to which they improve detection of different-sized polyps remains unclear. OBJECTIVE: This study compared the size-stratified efficacy of AI-assisted colonoscopy vs standard colonoscopy using the Hartung-Knapp-Sidik-Jonkman (HKSJ) method, and generated exploratory rankings while acknowledging all cross-platform comparisons are indirect. METHODS: This systematic review and network meta-analysis (NMA) searched PubMed, Embase, Cochrane CENTRAL, and Web of Science from inception to July 25, 2026, supplemented by citation searching. We included randomized controlled trials (RCTs) comparing AI-assisted vs standard colonoscopy in adults (≥18 years of age), reporting mean polyp detection counts stratified by size (≤5 mm, 6-9 mm, and ≥10 mm). Two reviewers screened studies, extracted data, and assessed risk of bias using the Cochrane Risk of Bias 2.0. We conducted frequentist NMA using the HKSJ method with restricted maximum likelihood estimation, calculated 95% prediction intervals (PIs), and assessed heterogeneity using I2 and τ2. Certainty of evidence was rated using the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) framework. RESULTS: A total of 13 RCTs (4156 participants) compared 8 AI systems to standard colonoscopy, forming a network without direct AI comparisons. For diminutive polyps (≤5 mm), AI showed a modest advantage (standardized mean difference [SMD] 0.21, 95% CI 0.07 to 0.35, 95% PI -1.12 to 1.54), but substantial heterogeneity (I2=86.6%) and wide PI crossing the null indicated high uncertainty. EndoScreener showed the most consistent evidence (SMD 0.36, 95% CI 0.18-0.54). For small and large polyps, effects were minimal (SMD 0.02, 95% CI -0.02 to 0.06, 95% PI -0.03 to 0.07; SMD 0.01, 95% CI 0.00-0.02, 95% PI -0.01 to 0.03). GRADE certainty was very low for diminutive polyps and low for small and large polyps. Sensitivity analysis excluding Tianjin YuJin did not materially change findings. CONCLUSIONS: AI may modestly enhance diminutive polyp detection, but effects on small and large polyps are minimal, with no platform superiority. Given very low to low certainty, findings are hypothesis-generating. This exploratory NMA provides size-stratified comparisons that can inform future head-to-head trial design. Unlike prior reviews aggregating all polyp sizes, we show the overall AI benefit is driven by diminutive polyp detection, providing a framework for targeted deployment-prioritizing AI for diminutive polyp screening, with limited value for larger lesions. Head-to-head trials are urgently needed. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD420251266932; https://www.crd.york.ac.uk/PROSPERO/view/CRD420251266932.

Colonoscopy↗

Optical adjuncts for enhanced colonoscopic diagnosis.

BACKGROUND: Optical techniques using previously unexploited properties of light interaction with tissue may be valuable in the detection, diagnosis and staging of colorectal neoplasia. METHODS: A Medline search (1990 to present) was conducted on optical diagnostics in the detection of colorectal neoplasia. The reference list of each identified article was reviewed for further relevant papers. RESULTS AND CONCLUSION: Chromoendoscopy is the only optical adjunct to colonoscopy that has been tested in large randomized clinical trials. It improves the detection of small and flat colorectal adenomas, and of neoplasia in chronic ulcerative colitis and hereditary non-polyposis colorectal cancer. All other techniques are the subject of ongoing research and the practicality of population screening with any of the methods has yet to be established. Optical techniques may, however, permit immediate clinical diagnosis, removing the need for histological analysis. They may also improve the diagnosis of early colonic neoplasia.

Colonoscopy↗

Fragile egos.

Explore the source record for details and available documents.

Colonoscopy↗