PubMed Health⌕ Search

PubMed · 7656563

Comparative mathematical analyses of freezing in lung and solid tissue.

Abstract

In contrast to most organs of the body, the lung is composed 80% of air and 20% of tissue. Because freezing of the lung is fundamental to cryomicroscopy, cryopreservation, and cryosurgery, mathematical analyses of freezing in lung and solid tissue were performed to determine differences in freezing behavior resulting from differences in tissue composition. A comparison of the cooling rates of these tissues is presented. At the microscopic level ultrarapid solidification is more rapid in the subpleural region of the lung than in the same region of solid tissue. In this region, the air insulates the lung tissue and prevents transfer of heat from surrounding regions. Cooling rates on the order of 10(6) K/s can be achieved in the pleura and outermost alveolar wall because their aggregate thickness is less than 5 microns in the rat. At the macroscopic level and after steady-state freezing has occurred, one-dimensional analyses show that freezing front propagation in the lung and solid tissue differs by less than 10%. This occurs even though the lung is less conductive than solid tissue; however, by having less heat storage capacity, the thermal diffusive property of lung is similar to that of solid tissue.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Y Lee, J Bastacky. 1995. Comparative mathematical analyses of freezing in lung and solid tissue.. https://doi.org/10.1006/cryo.1995.1029

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stochastic simulation of daily air temperature and precipitation from monthly normals in North America north of Mexico.

A simple, stochastic daily temperature and precipitation generator (TEMPGEN) was developed to generate inputs for the study of the effects of climate change on models driven by daily weather information when climate data are available as monthly summaries. The model uses as input only 11 sets of monthly normal statistics from individual weather stations. It needs no calibration, and was parameterized and validated for use in Canada and the continental United States. Monthly normals needed are: mean and standard deviation of daily minimum and maximum temperature, first and second order autoregressive terms for daily deviations of minimum and maximum temperatures from their daily means, correlation of deviations of daily minimum and maximum temperatures, total precipitation, and the interannual variance of total precipitation. The statistical properties and distributions of daily temperature and precipitation data produced by this generator compared quite favorably with observations from 708 stations throughout North America (north of Mexico). The algorithm generates realistic seasonal patterns, variability and extremes of temperature, precipitation, frost-free periods and hot spells. However, it predicts less accurately the daily probability of precipitation, extreme precipitation events and the duration of extreme droughts.

Air↗

Blends of poly(epsilon-caprolactone) and intermediate molar mass polystyrene as Langmuir films at the air/water interface.

Poly(epsilon-caprolactone)/polystyrene (PCL/PS) blends, where nonamphiphilic PS is glassy in the bulk state at the experimental temperature of 22.5 degrees C, are immiscible as Langmuir films at the air/water (A/W) interface. Surface pressure-area per monomer isotherm analyses indicate that the surface concentration of amphiphilic PCL is the only factor influencing the surface pressure below the collapse transition. For PS-rich blends, Brewster angle microscopy (BAM) studies at the A/W interface and atomic force microscopy studies on Langmuir-Schaefer films reveal that PS nanoparticle aggregates formed at very low surface pressures can form networks upon further compression. The morphologies seen in PS-rich blends (networklike rings) are consistent with a recent study of a nonamphiphilic polyhedral oligomeric silsesquioxane (POSS), octaisobutyl-POSS, blended with amphiphilic poly(dimethylsiloxane), suggesting that the nonamphiphilic PS aggregates at the A/W interface produce domains with dipole densities that differ from that of pure PCL. In all composition regimes, the amphiphilic PCL phase tends to spread and form a continuous surface layer at the A/W interface, while simultaneously improving the dispersion of nonamphiphilic PS domains. During film expansion, BAM images show a gradual change in the surface morphology from highly continuous networklike structures (PS-rich blends) to broken ringlike structures (intermediate composition) to small discontinuous aggregates (PCL-rich blends). This study provides valuable information on the morphological evolution of semicrystalline PCL-based polymer blends confined in a "two-dimensional" geometry at the A/W interface and fundamental insight into the influence of microstructure (domain size, phase-separated structures, crystalline morphology, etc.) on the interfacial properties of blends as Langmuir films.

Air↗

Prediction of air temperature for thermal comfort of people in outdoor environments.

Current thermal comfort indices do not take into account the effects of wind and body movement on the thermal resistance and vapor resistance of clothing. This may cause public health problem, e.g. cold-related mortality. Based on the energy balance equation and heat exchanges between a clothed body and the outdoor environment, a mathematical model was developed to determine the air temperature at which an average adult, wearing a specific outdoor clothing and engaging in a given activity, attains thermal comfort under outdoor environment condition. The results indicated low clothing insulation, less physical activity and high wind speed lead to high air temperature prediction for thermal comfort. More accurate air temperature prediction is able to prevent wearers from hypothermia under cold conditions.

Air↗