PubMed Health⌕ Search

PubMed · 7685264

Error bounds for EEG and MEG dipole source localization.

Abstract

General formulas are presented for computing a lower bound on localization and moment error for electroencephalographic (EEG) or magnetoencephalographic (MEG) current source dipole models with arbitrary sensor array geometry. Specific EEG and MEG formulas are presented for multiple dipoles in a head model with 4 spherical shells. Localization error bounds are presented for both EEG and MEG for several different sensor configurations. Graphical error contours are presented for 127 sensors covering the upper hemisphere, for both 37 sensors and 127 sensors covering a smaller region, and for the standard 10-20 EEG sensor arrangement. Both 1- and 2-dipole cases were examined for all possible dipole orientations and locations within a head quadrant. The results show a strong dependence on absolute dipole location and orientation. The results also show that fusion of the EEG and MEG measurements into a combined model reduces the lower bound. A Monte Carlo simulation was performed to check the tightness of the bounds for a selected case. The simple head model, the low power noise and the few strong dipoles were all selected in this study as optimistic conditions to establish possibly fundamental resolution limits for any localization effort. Results, under these favorable assumptions, show comparable resolutions between the EEG and the MEG models, but accuracy for a single dipole, in either case, appears limited to several millimeters for a single time slice. The lower bounds increase markedly with just 2 dipoles. Observations are given to support the need for full spatiotemporal modeling to improve these lower bounds. All of the simulation results presented can easily be scaled to other instances of noise power and dipole intensity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Mosher, M E Spencer, R M Leahy, P S Lewis. 1993. Error bounds for EEG and MEG dipole source localization.. https://doi.org/10.1016/0013-4694(93)90043-u

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A MAGIBU-based model for pediatric and juvenile CNS tumors: an in-house epigenetic decision-support framework compared with online DNA methylation classifiers.

Background: DNA methylation profiling is a tool that provides key support for central nervous system (CNS) tumor classification. However, diagnostically ambiguous pediatric cases may result in discordant outputs across classifiers. We developed MAGIBU, a cross-platform, projection-based framework that embeds individual methylomes into a fixed CNS reference landscape, ranking diagnostic entities by local epigenetic proximity to support clinician-led integrative diagnosis. Methods: As a proof-of-concept, we evaluated MAGIBU in eight morphologically challenging pediatric/juvenile CNS tumors with unresolved diagnoses after institutional and central pathology review. To establish a benchmark in the absence of a definitive histopathological ground truth, a consensus epigenetic reference was defined a priori for cases showing concordant results between the Heidelberg CNS Tumor Methylation Classifier and Methylscape Analysis. Comparisons were also performed with Epigenomic Digital Pathology (EpiDiP). To validate MAGIBU beyond this discovery cohort, performance was assessed at the family level across the CNS methylation spectrum (n = 678, 28 methylation families), on non-array platforms (whole-genome bisulfite sequencing and Oxford Nanopore), and in a focused analysis of the low-grade glioma and diffuse midline glioma compartment across four independent cohorts (n = 670). Results: In the discovery cohort, MAGIBU achieved high concordance with the consensus reference (Cohen's κ = 0.855), outperforming EpiDiP (κ = 0.278), which frequently placed low-grade tumors in proximity to higher-grade reference regions. Conclusions: MAGIBU provides a stable, quantitative differential diagnosis framework that mitigates the limitations of rigid categorical assignments. By leveraging a distance-based proximity metric, it offers a transparent decision-support tool that integrates effectively with clinical, radiological, and molecular data. While performance is inherently dependent on reference atlas composition, MAGIBU represents a robust complementary approach for the diagnostic workup of ambiguous CNS tumors.

Brain↗

1q21.1 distal copy number variants are associated with cerebral and cognitive alterations in humans.

Low-frequency 1q21.1 distal deletion and duplication copy number variant (CNV) carriers are predisposed to multiple neurodevelopmental disorders, including schizophrenia, autism and intellectual disability. Human carriers display a high prevalence of micro- and macrocephaly in deletion and duplication carriers, respectively. The underlying brain structural diversity remains largely unknown. We systematically called CNVs in 38 cohorts from the large-scale ENIGMA-CNV collaboration and the UK Biobank and identified 28 1q21.1 distal deletion and 22 duplication carriers and 37,088 non-carriers (48% male) derived from 15 distinct magnetic resonance imaging scanner sites. With standardized methods, we compared subcortical and cortical brain measures (all) and cognitive performance (UK Biobank only) between carrier groups also testing for mediation of brain structure on cognition. We identified positive dosage effects of copy number on intracranial volume (ICV) and total cortical surface area, with the largest effects in frontal and cingulate cortices, and negative dosage effects on caudate and hippocampal volumes. The carriers displayed distinct cognitive deficit profiles in cognitive tasks from the UK Biobank with intermediate decreases in duplication carriers and somewhat larger in deletion carriers-the latter potentially mediated by ICV or cortical surface area. These results shed light on pathobiological mechanisms of neurodevelopmental disorders, by demonstrating gene dose effect on specific brain structures and effect on cognitive function.

Brain↗

Time course of EEG background activity level before spontaneous awakening in the second semester of human life.

This research aimed at investigating the time course of the EEG background activity level before spontaneous awakening out of rapid eye movement (REM) sleep, and non-rapid eye movement sleep with and without slow wave sleep (NREMSWS+, NREMSWS-) in the second semester of life. Twelve infants from 25 to 54 weeks of life were continuously monitored by polygraphic recording and behavioural observation during the night, and the EEG activity was analyzed by a method of automatic analysis. The EEG activation level increased before the awakening out of NREMSWS+ sleep, and was always high both in REM sleep and in NREMSWS-.

Brain↗