Monitoring ventilator function.

Abstract

Maintenance of the patient-ventilator system is the primary role of the respiratory care practitioner in the intensive care unit. Patient-ventilator system checks should include monitoring the patient's response to ventilation, evaluating function of the ventilator, maintaining ventilator settings according to physician orders, setting appropriate alarms, maintaining the integrity of the ventilator circuit and humidifier, and documenting all of the above. The concept of ventilator checks should be expanded and thus, the name changed to patient-ventilator system check to emphasize the importance of evaluating the patient. This article reviews the rationale for performing patient-ventilator system checks and measurements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R D Branson. 1995. Monitoring ventilator function.. https://pubmed.ncbi.nlm.nih.gov/7736264/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of beam blocking on linac head scatter factors.

PURPOSE: This study aimed to investigate the influence of beam blocking on head scatter within the context of a two-component x-ray source model. METHODS AND MATERIALS: Head scatter factors were measured for open rectangular fields defined by X and Y jaws and for fields blocked by a multileaf collimator (MLC) for a 6-MV photon beam from a Varian 2300CD accelerator. A simple formula based on consideration of linac head geometry and an x-ray source model was derived to determine when the head scatter factor for a shaped field depends only on jaw settings and when it is influenced by the blocking (cerrobend blocks or MLC) itself. RESULTS: Experimental data demonstrate that the assumption that head scatter is unaffected by the introduction of beam blocking is not always acceptable, particularly for fields blocked by an MLC. The ratios of open to blocked field dimensions were compared with simple functions characterizing the accelerator head geometry to predict changes in the behavior of head scatter factors observed experimentally. CONCLUSION: A simple formula can be used to determine when head scatter factors are influenced by beam blocking (cerrobend blocks or MLC).

Equipment Design

Differential dose delivery using a nondocking applicator for intraoperative radiation therapy.

PURPOSE: Although treatment of a field within a field to deliver a boost dose is quite common with external photon beam radiation therapy, the same is not always true with electron beam radiation or in intraoperative radiation therapy (IORT). The purpose of this work is to report the results and details of a new technique developed to treat a field within a field in intraoperative radiation therapy. METHODS AND MATERIALS: This technique makes use of the nondocking IORT system currently used at our institution. Treatment is given in two segments: the large field is first treated by using standard circular lucite cones; the second dose segment is delivered using a new circular brass cone designed to fit concentrically within the large lucite cone. RESULTS: Central axis depth dose, surface dose, output factors, and two-dimensional beam profiles have been measured for a 7 cm inner diameter (i.d.) flat lucite cone and 3.8 and 5 cm i.d. flat brass cones for electron beam energies ranging from 4-22 MeV. For different clinical target volumes, summed dose distributions differentially weighted in both energy and dose are presented. CONCLUSIONS: A simple technique for delivering differential dose in intraoperative radiation therapy is presented. The technique provides a method for escalating dose to higher values for a defined target volume.

Equipment Design

Broad laser indentation surface for retinal laser photocoagulation using indirect ophthalmoscopic delivery.

Laser photocoagulation of the peripheral retina is an important part of the therapeutic options for treating many vitreoretinal disorders, such as diabetic retinopathy, retinopathy of prematurity, and vitreoretinal degeneration. When preequatorial retinal photocoagulation is required, indirect delivery of laser energy is preferable, whether applied in the office setting or as part of a sterile surgical procedure. The anterior retina is usually visualized by scleral indentation employing a conventional scleral indentor or muscle hook. Under these circumstances the retinal surface presented frequently is too small and irregular, making efficient laser delivery unnecessarily laborious, resulting in a variable uptake of laser energy.

Equipment Design