PubMed Health⌕ Search

PubMed · 7760717

BOLD based functional MRI at 4 Tesla includes a capillary bed contribution: echo-planar imaging correlates with previous optical imaging using intrinsic signals.

Abstract

We show that the EPI time course in functional MR imaging at 4 Tesla displays a multiphasic response in response to photic stimulation. Focal areas of gray matter display an initial negative change in signal intensity that reaches a maximum of 1% about 2 s after the onset of photic stimulation. This component then changes sign, reaching a positive maximum about 5 s after the onset of the stimulus. Other areas, including those where draining veins are visible, show only a positive signal change, reaching a maximum of about 6% after the onset of the visual stimulus. These time constants are in very good agreement with published data obtained with intrinsic optical mapping techniques, where a deoxygenation phase has been shown to occur in functionally specific cortical columns, followed by an increase in blood volume which is more distributed in nature. Thus, we believe there is strong evidence that a sensitivity to capillary oxygenation state is present in high S/N functional MR images obtained with EPI at 4 T.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R S Menon, S Ogawa, X Hu, J P Strupp, P Anderson, K Uğurbil. 1995. BOLD based functional MRI at 4 Tesla includes a capillary bed contribution: echo-planar imaging correlates with previous optical imaging using intrinsic signals.. https://doi.org/10.1002/mrm.1910330323

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗