Gamma camera purchasing.

Abstract

The purchase of a new gamma camera is a major undertaking and represents a long-term commitment for most nuclear medicine departments. The purpose of tendering for gamma cameras is to assess the best match between the requirements of the clinical department and the equipment available and not necessarily to buy the 'best camera' [1-3]. After many years of drawing up tender specifications, this paper tries to outline some of the traps and pitfalls of this potentially perilous, although largely rewarding, exercise.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C P Wells, M Buxton-Thomas. 1995. Gamma camera purchasing.. https://pubmed.ncbi.nlm.nih.gov/7770241/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid evaluation of weekly scintillation camera resolution and linearity using the orthogonal tri-hole phantom.

OBJECTIVE: Both state and federal regulations require weekly monitoring of the resolution and linearity of the scintillation camera. Several phantoms are available to perform this quality control function. These include the quadrant bar. Bureau of Radiological Health (BRH), and orthogonal-hole (OH) phantoms. Each of these phantoms has either functional or temporal limitations on its use. The orthogonal tri-hole phantom (OTHP) was designed to overcome these limitations. METHODS: The OTHP consists of a precision-drilled lead plate sandwiched between two plastic plates. The OTHP has an active area of 15 in. x 20 in. which contains an orthogonal array of three-hole (2.5-mm, 3.0-mm, and 4.0-mm) clusters. Intrinsic and extrinsic images were acquired for the OTHP, OH phantom, BRH phantom and quadrant bar phantom. RESULTS: The OTHP test pattern allows resolution, linearity, object shape, and contrast to be evaluated simultaneously, either intrinsically or extrinsically, in a single image over the entire useful field-of-view. CONCLUSION: The OTHP provides a more quantitative evaluation of the quality control parameters than any other phantom currently available. The use of the OTHP results in cost savings since both camera and technologist time are reduced because only one image is required instead of the two or four needed for other phantoms.

Gamma Cameras

Superiority of triple-detector single-photon emission tomography over single- and dual-detector systems in the minimization of motion artefacts.

A patient motion-related artefact is one of the most important artefacts in single-photon emission tomography (SPET) imaging. This study evaluated the effect of the number and configuration of SPET detectors on motion artefacts. The following acquisition conditions were simulated based on original 360 degrees projection images: (1) single-detector 180 degrees rotation (S180), (2) a dual-detector rectangular (L-shaped) 180 degrees acquisition (D180L), (3) dual-detector cameras mounted opposite each other with 360 degrees acquisition (D360) and (4) triple-detector 360 degrees acquisition (T360). The motion artefacts were introduced using a syringe and a myocardial phantom. Clinical cases with technetium-99m methoxyisobutylisonitrile and thallium-201 studies were analysed to confirm the validity of this phantom simulation. The effect of continuous alternate rotation acquisition and summing the projections on the reduction of motion artefacts was investigated in each model. The effect of motion depended on the number and the configuration of the SPET detectors. A 1-pixel (6.4 mm) motion in the S180, D180L and D360 models generated only slight artefacts, and a 2-pixel motion led to an apparent decrease in activity or created hot areas in the myocardium. On the other hand, a T360 rotation created few artefacts even with a 2-pixel motion of the last quarter of the projections. Despite the difference in attenuation with 201Tl and 99mTc, similar artefact patterns were observed with both radionuclides in selected patient model studies. Continuous alternate rotation could reduce artefacts caused by less than a 2-pixel motion. In conclusion, calculating the average of the sum of the projections of triple-detector 360 degrees rotations with alternate rotation is the best method to minimize motion artefacts. This "averaging" effect of motion artefacts is a key to this simulation.

Gamma Cameras