PubMed HealthSearch

PubMed · 7772854

Re-using or mis-using?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Plowes. 1995. Re-using or mis-using?. https://pubmed.ncbi.nlm.nih.gov/7772854/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A pressure-distribution sensor (PDS) for evaluation of lip functions.

The purpose of this study was to develop and to test a pressure-distribution sensor (PDS) for evaluating lip functions. The PDS is fabricated as a disposable cartridge and is based on the principle of optical-pressure conversion used in tactile sensors of robot arms. Its advantages are in measuring sealing forces, contact area, and pressure-distribution patterns of the lips at maximum effort. We used the PDS to evaluate pressure-distribution patterns of long-face subjects with extremely large interlabial distances. The results suggest that the PDS is a useful device for evaluating lip sealing functions and their changes after orthodontic therapy or orthognathic surgery.

Disposable Equipment

Evaluation of flow rates for six disposable infusion devices.

The accuracy of flow was studied for six disposable infusion devices: Eclipse (Block Medical), Homepump (Block Medical), Intermate (Baxter Healthcare), MedFlo (Secure Medical), ReadyMED (McGaw), and SideKick (I-Flow). Each infusion device had a preset delivery rate of 100 mL/hr. Either 48 or 50 units of each device were filled with 100 mL of 0.9% sodium chloride injection. Flow was measured in a 60-mL syringe set 100 cm above the infusion device. The volume infused was recorded over 60 minutes at 5-minute intervals. Of the six devices tested, Homepump demonstrated the least variability in flow. The mean percentage of initial volume infused at 60 minutes was 93.7% for the Homepump, 92.4% for the MedFlo, 91.9% for the SideKick, 88.7% for the ReadyMED, 87.3% for the Eclipse, and 83.4% for the Intermate. The Intermate was the only device with a mean overall infusion rate outside the manufacturer's specifications of +/- 15%. The SideKick's mean infusion rate exceeded the +/- 15% range during the first half of the infusion. None of six disposable infusion devices delivered 100% of the volume to be infused within 60 minutes. Of the devices tested, the Homepump demonstrated the least variability in flow and the most complete volume delivery.

Disposable Equipment