PubMed HealthSearch

PubMed · 7784813

Disk diffusion susceptibility tests: need for laboratory-specific breakpoints.

Abstract

Significant changes were observed in the measured resistance levels of Escherichia coli and Staphylococcus aureus when the Biodisk disk susceptibility test method used in 1992 was replaced with another commercial method, Oxoid. For example, when non-species-specific breakpoints were used, the frequency of cephalotin-resistant E. coli was 12% of all isolates in 1992 but only 4% in 1993; the corresponding figures for the intermediately resistant isolates were 84% and 8%. The population distribution histograms were however, practically unchanged. Thus, the resistance percentages apparently did not reflect the real development of resistance. Similar findings were also made for several other antimicrobials. Susceptibility test breakpoints should therefore be examined separately for all bacterial species in each laboratory, and the application of adjusted laboratory-specific breakpoints should be considered. For this purpose, the WHONET computer program provides excellent assistance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Manninen, E Eerola, P Huovinen. 1995. Disk diffusion susceptibility tests: need for laboratory-specific breakpoints.. https://doi.org/10.3109/00365549509018971

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rapid method for the determination of ampicillin residues in animal muscle tissues by high-performance liquid chromatography with fluorescence detection.

A rapid and sensitive HPLC method was developed for the determination of ampicillin residues in muscle tissues of beef, pork, chicken and catfish. Muscle tissues were blended with a food processor into paste. A 5-g aliquot of the blended tissues was homogenized with 14 ml of 0.01 M phosphate buffer (pH 4.5) using a tissue homogenizer. Proteins were precipitated with the addition of 1 ml trichloroacetic acid (75%, w/v) followed by centrifugation. After filtration, 1 ml of the supernatant was reacted with formaldehyde under acidic and heating conditions. The ampicillin fluorescent derivative was then analyzed by reverse phase HPLC with fluorescence detection. Recoveries of spiked ampicillin at 5, 10 and 20 ng/g were >85%, with coefficients of variation <5%. The limit of detection and limit of quantitation for ampicillin in the tissues were 0.6 ng/g and 1.5 ng/g, respectively. The method is also applicable to the analysis of ampicillin residue in dry milk powder.

Ampicillin