Effect of data compression on quantitative coronary measurements.

Abstract

Digital coronary and left ventricular angiography demand high transfer rates and very large data storage if all the clinical data are to be achieved. If appropriate compression schemes were available without compromising the quality and resolution of the image data, such demands could be lessened. In this study we compared the influence of different compression factors of the Adaptive Real Time Image Compression (ARTIC) scheme used on the Philips DCI-SX systems on coronary measurements assessed with the Automated Coronary Analysis (ACA) package. Loss-free acquired images of size 512(2) x 8 bits, which had been stored digitally on tape, were reloaded into the DCI with compression factors of 2, 3, and 4; only the factor 2 is loss free. To evaluate the effect of the different data compressions on the accuracy of the measurements, the diameters of a vessel phantom (tube sizes ranging from 0.687 to 5.062 mm) were determined. To evaluate the reproducibility of the results, the intraobserver variability was determined for the different compression factors from 40 coronary obstructions. The differences in the reference diameter measurements of the vessel phantom were -0.03 +/- 0.06 mm, 0.01 +/- 0.07 mm, and 0.04 +/- 0.08 mm for the compression factors 2 (loss free), 3, and 4, respectively. The results were not statistically significantly different. The intraobserver variabilities in the obstruction diameter measurements of the coronary obstructions were -0.04 +/- 0.13 mm, 0.00 +/- 0.14 mm, and 0.02 +/- 0.13 mm for the compression factors 2, 3 and 4, respectively. The intraobserver variabilities in the reference diameter measurements were -0.02 +/- 0.12 mm, 0.01 +/- 0.09 mm, and 0.03 +/- 0.09 mm for the compression factors 2, 3, and 4, respectively. The intraobserver variabilities of the percent diameter stenosis were 0.96 +/- 4.19%, -0.01 +/- 4.88% and -0.04 +/- 4.68% for the compression factors 2, 3, and 4, respectively. None of these differences were statistically significant. Both from a qualitative and quantitative point of view, data compression factors 3 and 4 are acceptable in digital coronary arteriography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G Koning, B A van Meurs, H Haas, J H Reiber. 1995. Effect of data compression on quantitative coronary measurements.. https://doi.org/10.1002/ccd.1810340421. https://pubmed.health/record/pubmed%3A7788699/effect-of-data-compression-on-quantitative-coronary-measurements

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Repeat right transradial percutaneous coronary intervention in a patient with dextrocardia: the right approach to the right-sided heart.

Dextrocardia (DC) is a rare cardiac condition in which the cardiac location, as well as apex, is rightwardly displaced. As the incidence of atherosclerotic disease is similar to that of the general population, there have been few reports of percutaneous coronary interventions (PCIs) in these patients. Proposed technical strategies for successful angiography and PCI in DC include counter-directional torquing of the catheter, as well as right-left mirror-image inversion angiographic views. All previous reports of DC PCIs have been via transfemoral access.We present a case of successful repeat transradial PCI in a patient with DC. This is first report of transradial coronary angiography, PCI, or repeat PCI in a DC patient. A literature review of technical considerations, including our own recommendations for guide catheter selection, are discussed. We also review the anatomic variations and epidemiology of DC. Although access complications for transradial PCI is known to be lower than that of the transfemoral approach, challenges in technique and concern of repeat access have limited the popularity of the former. Our report demonstrates the safety and feasibility of transradial angiography, PCI, and even repeat PCI, in the rare patient with DC.

Coronary Angiography↗