Cyclic polyamine ionophore for use in a dibasic phosphate-selective electrode.

Abstract

A cyclic polyamine, 3-decyl-1,5,8-triazacyclodecane-2,4-dione (N3-cyclic amine), was used as the ionophore for a dibasic phosphate-selective electrode. This electrode exhibited a linear response between 1.0 mumol/L and 0.1 mol/L dibasic phosphate activity with a near-Nernstian slope of approximately -29 mV per activity decade. The electrode selectivity for dibasic phosphate over other commonly occurring anions was evaluated. A mechanism for the selectivity of the electrode toward HOP4(2-) ions is postulated to be a function of the size and charge of the N3-cyclic amine ionophore relative to the size and charge of HPO4(2-) ions. The electrode's superior selectivity and sensitivity make possible the direct measurement of phosphate activity in a wide variety of applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C M Carey, W B Riggan. 1994-11-01. Cyclic polyamine ionophore for use in a dibasic phosphate-selective electrode.. https://doi.org/10.1021/ac00093a009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Enhancement of enzyme-activated 1,2-dioxetane chemiluminescence in membrane-based assays.

Processes for enhancing the chemiluminescent signal generated by enzyme-activated 1,2-dioxetanes have been developed for membrane-based assays in which detection is done using a charge-coupled device (CCD) camera or X-ray film. The enhancement is demonstrated using slot-blots of biotinylated lambda DNA in conjunction with an avidin-alkaline phosphatase conjugate. For detection with a CCD camera, the nylon membrane is dried after processing and incubation in dioxetane substrate solution and heated to temperatures of 50 to 80 degrees C during detection. Up to a 100-fold signal increase is obtained using this enhancement process compared to the conventional detection procedure, in which the blot is kept saturated with substrate solution in a sealed plastic bag during detection. For detection with X-ray film, a fivefold increase in signal intensity is realized by drying the membrane before exposure to the film. These enhancement processes greatly reduce the time required for detection in membrane-based assays.

Heterocyclic Compounds

[The effect of various structural features in molecules of derivatives of pyrene and its heterocyclic analogs on its mutagenic activity].

The mutagenic potency of five acetyl and acetylamine derivatives of nitropyrene and 15 heterocyclic analogues of pyrene was studied in the strain Salmonella typhimurium TA1538. A significant impact of the electron-withdrawing acetyl group in the para-position on the mutagenic activity of derivatives of nitropyrene was shown. The para position of nitro and amino groups as well as of the amino and carboxyl group was also responsible for the mutagenic activity. A proposal for the existence of several cellular mechanisms of activation of molecules of heterocyclic analogues of pyrene is presented.

Heterocyclic Compounds