PubMed HealthSearch

PubMed · 7803360

Contrast sensitivity testing in clinical practice.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Moseley, A R Hill. 1994. Contrast sensitivity testing in clinical practice.. https://doi.org/10.1136/bjo.78.10.795

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effects of contrast on perceived depth and depth discrimination.

The contrast dependence of perceived depth was quantified through a series of depth matching experiments. Perceived depth was found to be a power law function of contrast. In addition, subjects exhibited a large uncrossed depth bias indicating that low contrast test patterns appeared much farther away than high contrast patterns of equal disparity. For disparities in the range of +/- 4.0 arc min, matching disparities for low contrast patterns were shifted in the uncrossed direction by the same amount. In other words, while the magnitude of the uncrossed depth bias is a power law function of contrast, it is constant with respect to disparity. In a second series of experiments, the contrast dependence of stereo increment thresholds was measured. Like perceived depth and stereoacuity, stereo increment thresholds were found to be a power law function of contrast. These results suggest that contrast effects occur at or before the extraction of depth and have implications for the response properties of disparity-selective mechanisms.

Contrast Sensitivity

Moving segments region of interest attenuator for x-ray fluoroscopy.

Region of interest (ROI) imaging has previously been proposed as a means of reducing x-ray fluoroscopy radiation dose. Previous ROI attenuators made of partially attenuating metal plates change beam quality, which may lead to uncertainty in image restoration procedures. The design and construction of a prototype moving segments ROI attenuator (MS-ROI), which maintains beam quality across the whole field of view is described. The x-ray beam intensity is halved by 36 lead segments which are rapidly rotated between the x-ray tube and patient, with a central hole projecting a circular ROI at full intensity. Image processing techniques with automatic detection of the ROI boundary were used to homogenize image brightness across the whole image. Images restored using these techniques were judged to be visually acceptable, with a good match between pixel values inside and outside the ROI. Image contrast within the ROI was improved by 18% due to reduced scatter and veiling glare from the periphery. The introduction of the MS-ROI attenuator also results in a 48% increase in statistical noise in the area outside the ROI, with no significant change in object contrast. The patient entrance dose measured using the dose area product (DAP) method was reduced by 53.4% under manual exposure control, with the dose to operators reduced by 48.4% under automatic brightness control. Further work is needed to determine whether the attenuator can be used with pulsed fluoroscopy, and to reduce vibrational effects on the ROI boundary. The MS-ROI attenuator provides a more constant ratio of central-to-peripheral image intensity, and maintains uniform beam quality and image contrast across the whole image in comparison to simple metal plate attenuators.

Contrast Sensitivity

Functional architecture of long-range perceptual interactions.

The pattern of lateral interactions in the primary visual cortex, which has emerged from recent studies, conforms to the grouping rules of similarity, proximity, smoothness and closure. The goal of this paper is to understand the perceptual salience of oriented elements that are specifically organized to form a smooth contour. An overview of recent studies, in combination with new experimental results, is presented here to emphasis the idea that visual responses depend on input from both the center and the surround of the classical receptive field (CRF). It is assumed that normal lateral interactions produce a neuronal network that is formed by two antagonistic mechanisms: (i) excitation, that is spatially organized along the optimal orientation (collinear), and is predominant near the contrast threshold of the neuron, and (ii) inhibition, that is less selective and is distributed diffusely around the cell's response field. Thus, the inputs from the CRF and the anisotropic surround are summated non-linearly. The specificity of the facilitation and suppression along the collinear direction suggests the existence of second-order elongated collinear filters, which may increase the response similarity between neurons responding to elongated stimulus, thus may enhance the perceptual salience of anisotropic configurations such as contours. This causal connection is particularly evident in amblyopes, where abnormal development of the network results in the abnormal perception of contours.

Contrast Sensitivity