PubMed Health⌕ Search

PubMed · 7808612

The application accuracy of stereotactic frames.

Abstract

The purpose of incorporating stereotactic methodology into neurosurgical operations is to achieve a consistently high degree of accuracy in localizing intracranial targets. Therefore, the limits of resolution for the operation are a function of the accuracy of the particular stereotactic frame system. The total clinically relevant error (application accuracy) comprises errors associated with each procedural step, including imaging, target selection, vector calculations, and the mechanical errors of stereotactic frames. To evaluate these parameters, a systematic error analysis was carried out with four commonly used stereotactic devices: the Brown-Roberts-Wells, the Cosman-Roberts-Wells, the Kelly-Goerss COMPASS (modified Todd-Wells), and the Leksell frames. Over 21,500 independent accuracy test measurements were made with 11,000 computed tomograms. The results suggest a potentially significant degree of error in the application accuracy of all stereotactic instruments, which is accentuated by but not entirely due to imaging-associated errors. Clinically encountered levels of weightbearing by stereotactic frames may have a pronounced effect on their mechanical accuracy. Both the reapplication of aiming arc assemblies and the use of phantom base units introduce independent sources of mechanical inaccuracy into stereotactic procedures. The scope of individual error values and their determining factors must be considered with every clinical use of stereotactic frame systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Maciunas, R L Galloway, J W Latimer. 1994. The application accuracy of stereotactic frames.. https://doi.org/10.1227/00006123-199410000-00015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A penalized likelihood approach to magnetic resonance image reconstruction.

Currently, images acquired via magnetic resonance imaging (MRI) and functional magnetic resonance imaging (fMRI) technology are reconstructed using the discrete inverse Fourier transform. While computationally convenient, this approach is not able to filter out noise. This is a serious limitation because the amount of noise in MRI and fMRI can be substantial. In this paper, we propose an alternative approach to reconstruction, based on penalized likelihood methodology. In particular, we focus on non-linear shrinkage estimators and show that this approach achieves a great reduction in integrated mean squared error (IMSE) of the estimated image with respect to the currently used estimator. This approach is extremely fast and easy to implement computationally. In addition, it can be combined with various alternative approaches to MR image reconstruction and can be easily adapted to other, non-MRI contexts, in which the observed data and the quantities of interest are related via a linear transform.

Brain Diseases↗