PubMed Health⌕ Search

PubMed · 7814255

A study of the angular dependence problem in effective dose equivalent assessment.

Abstract

The newly revised American National Standard N13.11 (1993) includes measurements of angular response as part of personnel dosimeter performance testing. However, data on effective dose equivalent (HE), the principle limiting quantity defined in International Commission on Radiological Protection (ICRP) Publication 26 and later adopted by U.S. Nuclear Regulatory Commission (NRC), for radiation incident on the body from off-normal angles are little seen in the literature. The absence of scientific data has led to unnecessarily conservative approaches in radiation protection practices. This paper presents a new set of fluence-to-HE conversion factors as a function of radiation angles and sex for monoenergetic photon beams of 0.08, 0.3, and 1.0 MeV. A Monte Carlo transport code (MCNP) and sex-specific anthropomorphic phantoms were used in this study. Results indicate that Anterior-posterior (AP) exposure produces the highest HE per unit photon fluence in all cases. Posterior-anterior (PA) exposure produces the highest HE among beams incident from the rear half-plane of the body. HE decreases dramatically as one departs from the AP and PA orientations. The results also indicate that overestimations caused by using isotropic dosimeters in assessing effective dose equivalent from near-overhead and near-underfoot exposures are 550%, 390%, and 254% for 0.08, 0.3, and 1.0 MeV, respectively. Comparisons of the angular dependence of HE with those based on the secondary quantities defined in International Commission on Radiation Units and Measurements (ICRU) Reports 39, 43, and 47 show significant differences. This paper discusses why more accurate assessments of HE are necessary and possible. An empirical equation is proposed which can be used as the optimum dosimeter angular response function for radiation angles ranging from 0 degrees to 90 degrees for dosimeter calibration, performance testing, and design.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

X G Xu, W D Reece, J W Poston. 1995. A study of the angular dependence problem in effective dose equivalent assessment.. https://doi.org/10.1097/00004032-199502000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal designs for radiation retention with poisson correlated response.

In this paper we describe a non-linear model with correlated observations which accounts for the elimination rate of radiation in the lung of individuals who have been exposed to an accidental intake at some time. The response is then modelled as a conditional Poisson distribution. When the leak is moderate or the size of the particles is large a theoretical justification of this assumption is given and D-optimal designs are computed.

Dose-Response Relationship, Radiation↗

Nanodosemeters based on gel scintillators.

The feasibility of a nanodosemeter based on a liquid scintillator cocktail of four components (ethoxylated nonylphenol, pseudocumene, water and a lipophilic mixture) is studied. The dosemeter can work in distinct gel phases, for which the radioactive substance can be confined inside aqueous nanoscale structures of different size. For water volumes ranging 0-15%, it results in a gel with micelles of 4 nm radius. For water volumes ranging 30-50%, the resulting liquid-crystal gel contains nanostructures of approximately 20 nm radius. The low-energy electron emission arising from the decay of (3)H and (55)Fe is counted in a commercial liquid-scintillation counting spectrometer for both homogeneous and gel samples. The counting efficiency gap between the two phases is used to compute the average energy deposited inside the micelle.

Dose-Response Relationship, Radiation↗

Stereotactic radiosurgery and radiation therapy for spinal tumors.

Spinal tumors constitute 15% of all CNS neoplasms. Radiation therapy can be administered for palliation of pain and spinal cord compression. However, the amount of radiation that can be administered is often limited by the tolerance of the spinal cord, especially in cases where prior radiation therapy has been given. Stereotactic radiosurgery and radiotherapy allow the delivery of a higher dose of radiation to spinal lesions, while limiting the spinal cord dose to below the tolerance level. These are technically demanding procedures and should be performed only when proper equipment and expertise are available. Data on spinal stereotactic radiosurgery and radiotherapy have emerged in recent years. This review summarizes the clinical applications of stereotactic radiosurgery and radiotherapy for spinal tumors.

Dose-Response Relationship, Radiation↗