PubMed Health⌕ Search

PubMed · 7846758

Just plain vanilla?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R C Prince, D E Gunson. 1994. Just plain vanilla?. https://doi.org/10.1016/0968-0004(94)90049-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design of an innovative framework based hybrid catalyst for simultaneous and sensitive monitoring of food additive and preservative of vanillin and nitrite in direct samples.

As vanillin (VAN) and nitrite (NIT) contamination in the food chain poses substantial threats to environmental and public health, rapid and portable detection is essential. The present study presents the first electrochemical sensor report based on a hybrid composite of Ni-TPA-MOF and MoS2/Co3O4. The oxidation of VAN and NIT exhibited sharp peaks and less over-potential on Ni-TPA-MOF/MoS2/Co3O4/GCE than on control electrode surfaces. On modified composite electrode surfaces, pH and scan rate were investigated for VAN and NIT. Further, the oxidation current exhibited high linearity at VAN and NIT concentrations of 5 nM-1000 μM and 3 nM-1250 μM, with detection limits of 0.102 nM and 0.073 nM (S/N = 3). We also applied anti-interfering ability (five/ten-fold excess of co-interfering compounds) and practical tests to various food-based real samples, with high recoveries of 98.85-102.41%. This study highlights the catalytic properties of Ni-TPA-MOF/MoS2/Co3O4 and demonstrates the sensor as a promising tool for food safety.

Benzaldehydes↗

Interfacial engineering of cobalt tungstate-halloysite nanotube nanocomposite for electrochemical detection of synthetic vanillin in food matrices.

In processed foods and medicine, synthetic vanillin is widely used, although excessive intake poses toxicological risks. Due to the rising usage of synthetic vanillin in food products and associated health hazards, quick, sensitive, and reliable analytical methods are needed to precisely measure vanillin in complex food matrices. This work introduces a CoWO4@F-HNT/GCE nanocomposite as an efficient electrocatalytic modifier for glassy carbon electrodes aimed at trace-level synthetic vanillin detection. Structural and microscopic analyses confirmed phase-pure monoclinic CoWO4, preservation of the tubular aluminosilicate framework, and homogeneous nanoparticle anchoring on F-HNT. Differential pulse voltammetry provided a broad linear range from 0.01 to 372.14 μM and a low detection limit of 4.3 nM, together with excellent selectivity against common interferents, good cycling stability, and high inter-electrode reproducibility. These characteristics position the CoWO4@F-HNT-modified electrode as a cost-effective and reliable platform for on-site quality control of synthetic vanillin in complex food matrices.

Benzaldehydes↗

Development of a LC-ESI/MS/MS assay for the quantification of vanillin using a simple off-line dansyl chloride derivatization reaction to enhance signal intensity.

Vanillin is responsible for producing the familiar smell of vanilla. Vanillin has many similarities with other flavor phenolic compounds and could potentially show similar pharmacological activity. A previously published analytical method was adapted, developed and tested. Vanillin was extracted from rat plasma using protein precipitation with acetone. Prior to LC-ESI/MS/MS analysis, an aliquot of the supernatant was used to proceed to the derivatization of vanillin and the internal standard with dansyl chloride to enhance signal intensity in positive electrospray mode. The chromatography was performed on a 100 x 2.1 mm C8 column and an isocratic mobile phase composed of 75:25 acetonitrile:0.5% formic acid in water with a flow rate fixed at 500 microL/min. A linear (weighted 1/concentration) relationship was used to perform the calibration over an analytical range of 10-10,000 ng/mL. The intra-batch precision and accuracy at the limit of quantitation (10 ng/mL), medium (500 ng/mL) and high (10,000 ng/mL) concentrations were 10.7, 7.0 and 7.2% and 103.5, 108.0 and 100.1%, respectively. The observed recovery was greater than 87% and no significant ionization suppression or matrix effect was observed. This LC-ESI/MS/MS method for the determination of vanillin in rat plasma provided results within generally accepted criteria used for bioanalytical assay.

Benzaldehydes↗