PubMed HealthSearch

PubMed · 7860839

Modeling acoustic backscatter from kidney microstructure using an anisotropic correlation function.

Abstract

Techniques for investigating acoustic backscatter from anisotropic biological tissues are examined. This empirical study combines single-scatter theory with the known elastic properties and histology of the renal cortex to predict the backscatter coefficient from kidney parenchyma. A transverse isotropic correlation model is developed to explain how backscattered energy, which varies with the incident sound wave direction, is related to the anisotropic structure of the tissue. From the results we conclude that renal morphology scatters sound incoherently, and that complex mixtures of scattering structures of different sizes, number densities, and scattering strengths can be distinguished by analyzing backscatter in specific frequency channels--a spectroscopic approach. A K-space description of backscatter measurements from kidney cortex, including the effects of anisotopy, provides further support of our hypothesis regarding sources of acoustic scattering.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M F Insana. 1995. Modeling acoustic backscatter from kidney microstructure using an anisotropic correlation function.. https://doi.org/10.1121/1.412287

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acoustic assessment of the physical integrity of Björk-Shiley convexo-concave heart valves.

BACKGROUND: Several lines of evidence indicate a two-stage failure mode for the Björk-Shiley convexo-concave (C/C) heart valve, in which one of the two outlet strut legs separates from the flange before the other, potentially providing an opportunity to identify and prophylactically replace failure-prone valves. Radiographic single leg separation (SLS) detection, although successful, is subjective and skill intensive, implying a need for both an objective preliminary screen and subsequent corroboration of the radiographic findings. METHODS AND RESULTS: We developed a time-windowed, power density analysis of C/C valve closing sounds to detect the vibrational resonance that characterizes the presence of an intact outlet strut in clinically functioning, 29-mm-flange size C/C valves. Recordings from more than 800 patients enrolled in radiographic SLS detection studies were analyzed, and the assessment algorithm was evaluated through a blinded test of 32 study valves for which the true status became known consequent to an autopsy or surgical explantation. Valves were objectively scored on a 0-to- 1 scale, with 1 being assuredly intact and scores of < 0.50 indicating a probable SLS. All except five valves (incorrectly designated probable SLS) were classified correctly, for a sensitivity of 1.00 (95% confidence interval, 0.79 to 1.00) and a specificity of 0.69 (0.41 to 0.89). CONCLUSIONS: This level of accuracy is sufficient to serve as an effective preliminary screen, potentially allowing a threefold concentration of SLS prevalence among the C/C valves of patients undergoing radiographic assessment. The value of acoustic classification in avoiding unnecessary operations prompted by false-positive radiographs is less certain.

Acoustics

Detection of adenoidal hypertrophy using acoustic rhinomanometry.

Adenoidal hypertrophy is the commonest cause of nasal obstruction in the pediatric population. It may cause marked morbidity as regards respiratory physiology, facial growth and middle ear function. Determination of adenoidal presence and size is not easy. Nasal endoscopy and radiology are the most accepted modes of diagnosis and each has its disadvantages. We have used acoustic rhinometry to determine the size of adenoids. Changes in nasal volume and resistance were recorded and an easy formula was devised to determined adenoid size. This technique is easy, non-invasive and reproducible with a 93.5% predictive value.

Acoustics

Acoustic evaluation of the efficacy of medical therapy for allergic nasal obstruction.

Acoustic rhinometry (AR) was used for objective measurements of nasal cavity dimensions in conjunction with a 100-mm horizontal visual analogue scale (VAS) for simultaneous subjective assessments of nasal sensations of airflow. Studies were conducted on 45 patients with perennial allergic rhinitis before, during and after a 2-week period of treatment with oral emedastine difumarate, azelastine hydrochloride, and xiao qing long tang (a homeopathic decongestant), as well as intranasal fluticasone propionate aqueous nasal spray. During the treatment period, there was a significant increase in the right and left minimum cross-sectional areas (MCA) of the nose and/or nasal cavity volumes (NCV) in all groups. The average increase in MCA ranged from 21-39% after 1 week of treatment and 16-39% after 2 weeks, whereas that in the NCV ranged from 16-24% and 19-24%, respectively. Post-treatment measurements were not significantly different from the corresponding pre-treatment ones. These findings were in close agreement with that obtained with VAS, demonstrating that AR can be used to validate the application of VAS in the evaluation of nasal airflow during medical therapy.

Acoustics