A program for analyzing enzyme rate data obtained from a microplate reader.

Abstract

A computer program (microplate analysis [MPA] program) is described that allows manipulation of kinetic data obtained from a microplate reader. It is particularly useful for obtaining enzyme velocities from microplate data. Data can be displayed either as an 8 x 12 grid which shows all microplate wells at low resolution or as single enzyme progress curves which show the reaction time course in greater detail and allow data manipulation (single curve mode). In the single curve mode, the X-axis of the progress curves can be displayed either as discrete time points numbered from the first to the last or as real time in seconds. The program can calculate the maximum, minimum or initial reaction rate by either linear or robust regression. In the single curve mode, the user can control the range of data points included in the regression analysis and the number of data points over which the rate is averaged. In this way, the maximum (or minimum) rate within a specific range of data can be determined. The major advantage of the MPA program is that the range settings are specific to each well. This gives the user complete control over the presentation and calculation of the kinetic data. The MPA program requires an AS-CII file containing data blocks of 96 sequential absorbance readings for each time point and the time interval between successive absorbance readings.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S P Brooks. 1994. A program for analyzing enzyme rate data obtained from a microplate reader.. https://pubmed.ncbi.nlm.nih.gov/7873186/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Linearity and the limitations of least squares calibration.

The magnitude of errors that can arise in practice from the limitations of the least squares method of calibration is estimated. Data generated from y = xn (0.7 < or = n < or = 1.3 and 1 < or = x < or = 30, or < or = 60) was analysed by least squares regression. Each y-value was then presented to the linear model and an x-value predicted. The relative errors on small x-values reached 70% of the concentration value even when r2 exceeded 0.999. Estimates of the errors on each predicted x-value, determined from the standard errors of the slope and intercept failed to reveal large errors at small x-values. Reducing the range over which linear regression is performed improved the errors. Other data sets with a heteroscedastic error distribution show that linear regression by least squares can also lead to the rejection of methods that performed sufficiently well for their application. Heteroscedastic data may be treated by repeated measurements at the lower end of the range. Data from a validation of an HPLC method for isoflavones in legumes is used to show the errors in recovery when a check sample is presented to the instrument using a calibration which satisfies the linearity tests. It is recommended that both y- and relative x-residuals are inspected. It is proposed that over-reliance on linear calibration supported by r2 may make a major contribution to large, hitherto unexplained, inter-laboratory errors.

Calibration

Alternative method for determination of pyrimethamine in plasma by high-performance liquid chromatography.

A rapid, selective, sensitive and reproducible reversed-phase high-performance liquid chromatography (HPLC) procedure for the quantitative determination of pyrimethamine (PYR) in plasma is described. The procedure involved the two-step extraction of PYR and the internal standard, quinine (QN) with acetonitrile and dichloromethane at basic pH. Chromatographic separation consisted of the mobile phase (methanol-water containing 0.005 M octanesulfonic acid, 50:50, v/v) running through the column (Techopak-10 C18) at a flow-rate of 1.6 ml/min. Detection was at UV wavelength of 240 nm. The mean recoveries of PYR and QN at a concentration range of 50 and 500 ng/ml were 98.9 and 89%, and 94.7 and 96% for PYR and QN. The within-day coefficients of variation were 2.1-5.1% for PYR and 5.9% for QN. The day-to-day coefficients of variation were 2.1-4.1% for PYR and 5% for QN. The minimum detectable concentrations for PYR and QN in plasma were 3 and 10 ng/ml. The method was found to be suitable for use in clinical pharmacokinetic study.

Calibration

Characterization of a tunable optical parametric oscillator laser system for multielement flame laser excited atomic fluorescence spectrometry of cobalt, copper, lead, manganese, and thallium in buffalo river sediment.

A pulsed (10 Hz) optical parametric oscillator (OPO) laser system based on beta-barium borate (BBO) crystals and equipped with a frequency-doubling option (FDO) was characterized for use in laser excited atomic fluorescence spectrometry (LEAFS). This all-solid-state laser has a narrow spectral line width, a wide spectral tuning range (220-2200 nm), and a rapid, computer-controlled slew scan of wavelength (0.250 nm s-1 in the visible and infrared, and 0.125 nm s-1 in the ultraviolet). The output power characteristics (15-90 mJ/pulse in the visible, 1-40 mJ in the infrared, and 1-11 mJ in the ultraviolet), laser pulse-to-pulse variability (3-13% relative standard deviation, RSD, of the laser pulses), conversion efficiency of the FDO (2-17%), and spectral bandwidth in the visible spectrum (0.1-0.3 cm-1) were measured. The laser was used as the excitation source for a flame LEAFS instrument for which rapid, sequential, multielement analysis was demonstrated by slew scan of the laser. The instrument allowed about 640 measurements to be made in about 6 h, with triplicate measurements of all solutions and aqueous calibration curves, which yielded accurate analyses of a river sediment (National Institute of Standards and Technology, Buffalo River Sediment, 2704) for five elements with precisions < 5% RSD. Comparable or improved flame LEAFS detection limits over literature values were obtained for cobalt (2 ng mL-1), copper (2 ng mL-1), lead (0.4 ng mL-1), manganese (0.2 ng mL-1), and thallium (0.9 ng mL-1) by flame LEAFS.

Calibration