PubMed Health⌕ Search

PubMed · 788491

Computer detection of premature ventricular complexes: a modified approach.

Abstract

The accuracy of a data reduction system for arrhythmia detection in identifying premature ventricular complexes was evaluated in continuous tape records of 30 patients in a coronary care unit. Computer analysis was performed with a Honeywell 316 digital computer. Threshold values for dominant complexes were automatically determined and recognition of premature ventricular complexes was based on differences in QRS configuration, timing and T wave configuration from the dominant complexes. Verification of the computer accuracy in detecting premature ventricular complexes was made with visual beat by beat inspection using a two channel strip chart recorder with simultaneous recording of the electrocardiogram and computer signal. This procedure allowed for exact beat to beat correlation and, thus, absolute determination of false positive and false negative identification. From 0.5 to 6 continuous hours of monitoring per patient (average 3.5 hours) were analyzed for a total of 105 monitoring hours. The basic cardiac rhythms noted were normal sinus rhythm, sinue arrhythmia, sinus tachycardia, demand pacemaker rhythm, atrial fibrillation and atrioventricular (A-V) dissociation with junctional rhythm. Premature ventricular complexes were evident in 28 tapes (93 percent) including 12 (43% with multifocal premature ventricular complexes and 3 (11 percent) with ventricular tachycardia. The visual count of premature ventricular complexes totaled 7,921. Of these, 7,542 (95 percent) were properly classified by the computer. The total computer count was 8.717, representing a 13 percent false positive and 5 percent false negative identification rate. The false positive identifications of premature ventricular complexes occurred during periods of 10 seconds or more of continuous noise artifact and in the presence of atrial premature complexes conducted aberrantly. When these sections of tape were excluded, the computer had a less than 2 percent false negative and 3 percent false positive rate of identification of premature ventricular complexes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S B Knoebel, D E Lovelace, S Rasmussen, S E Wash. 1976. Computer detection of premature ventricular complexes: a modified approach.. https://doi.org/10.1016/0002-9149(76)90460-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Safety of nerve conduction studies in patients with implanted cardiac devices.

Patients with implanted cardiac devices and their physicians may defer important electrodiagnostic testing because of anxiety about potential negative effects on the device. To determine the safety of routine nerve conduction studies (NCS) in this population, 10 patients with permanent dual-chamber pacemakers of various types and five patients with implanted cardiac defibrillators (ICD) underwent nerve stimulation at sites commonly used during NCS. The implanted cardiac device was interrogated before and after the study and there was continuous monitoring of the surface electrocardiogram (ECG) and atrial and ventricular electrograms. Electrical impulses generated during routine NCS were never detected by the sensing amplifier and did not affect the programmed settings of the implanted cardiac device. We conclude that routine NCS is safe in patients with implanted cardiac pacemakers with bipolar sensing configurations and defibrillators.

Arrhythmias, Cardiac↗

[Pulmonary diseases and heart function].

The most severe cardiac sequel to lung disease is the load on the right ventricle due to pulmonary hypertension with the development of a cor pulmonale. This is characterized by hypertrophy and/or dilatation of the right ventricle because of a primary impairment of lung function and/or lung structure. The most important pathomechanisms for the development of pulmonary hypertension are vessel obliteration, mechanical lesions, primary vascular or extra-vascular inflammation and hypoxic vasoconstriction. Chronic obstructive pulmonary disease (COPD) is one of the most important reasons for chronic cor pulmonale. A further very common reason is obstructive sleep apnea syndrome, especially if combined with a COPD. In this case, the prevalence of cor pulmonale can reach 80%. The development of a chronic cor pulmonale is the most striking negative prognostic factor for these patients. Only 30% of COPD patients with cor pulmonale survive longer than 5 years, and only early detection of the disturbances to respiration which might potentially lead to cor pulmonale and their subsequent therapy are able to improve the patient's prognosis. Furthermore, pulmonary diseases may also have an impact on the left heart side in terms of an impairment of left heart function or by inducing severe arrhythmias . Thus, lung diseases may have both a significant impact on right and left heart performance.

Arrhythmias, Cardiac↗