PubMed HealthSearch

PubMed · 7897852

[Isopotential map].

Abstract

Isopotential map, constructed from ECGs of many body surface electrodes, is an expression of body surface distribution of cardiac potentials at a moment. This ECG mapping technique, providing far more information than the conventional 12-lead ECG recordings, has proved moving multiple dipoles of the heart as electric power generator, and has clarified break through minimum indicative of the right ventricular epicardial depolarization. It is also utilized for diagnosis of right ventricular or posterior myocardial infarction, left ventricular hypertrophy, localization of accessory pathway in WPW syndrome, indication for intervention in acute myocardial infarction, identification of responsible coronary artery in angina pectoris, risk of ventricular tachycardia etc. Further information on the heart will be expected through this mapping technique.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Ichihara. 1995. [Isopotential map].. https://pubmed.ncbi.nlm.nih.gov/7897852/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

ECG-manifest and ECG-silent dipyridamole technetium-99m sestamibi SPET perfusion defects in patients with ischaemic heart disease.

At dipyridamole myocardial scintigraphy, perfusion defects are seldom backed up by significant ECG changes. This would suggest myocardial blood flow heterogeneity, rather than true ischaemia, as the cause of the scintigraphic abnormalities. Electrocardiographic surface mapping has been documented to be more accurate than standard 12-lead ECG in the detection of provoked ischaemia. Thus, to investigate the relationship between ECG changes and perfusion abnormalities, body surface maps were recorded during dipyridamole infusion in 55 subjects (11 normals and 44 patients with ischaemic heart disease) undergoing dipyridamole technetium-99m sestamibi single-photon emission tomography (SPET). All had a normal resting ECG. The extent and severity of the sestamibi defect were quantified. New negative areas in the isointegral maps and rest-dipyridamole map differences >2 SD from normal limits were considered abnormal. After dipyridamole in normals, neither perfusion defects nor >/=1 mm ST segment depression on 12-lead ECG nor new negative areas in isointegral maps occurred. In patients, dipyridamole induced new perfusion defects in 35 (80%) but ST segment depression in only 18 (41%, P<0.001). Of the 35 patients with perfusion defects, 17 (49%, group 1) showed ST segment depression, while the other 18 (51%, group 2) did not. Abnormal body surface maps were found in 100% of group 1 and 88% of group 2 patients (NS). In group 1, the provoked hypoperfusion was of greater extent (P=0.007) and severity (P=0.01) and the onset of map abnormalities was significantly earlier (P<0. 001) than in group 2; time to map abnormalities was also significantly shorter than time to ST segment depression (P=0.01). In the 35 patients with complete scintigraphic, body map and angiographic data, the severity of reversible perfusion defect proved to be the strongest correlate of ST segment depression upon logistic regression analysis. Thus, sestamibi SPET abnormalities after dipyridamole are almost always associated with electrical changes on body surface maps, suggesting myocardial ischaemia as their cause. The much less common 12-lead ECG changes are slower to appear and reflect a more severe hypoperfusion.

Body Surface Potential Mapping

A comparison of volume conductor effects on body surface Laplacian and potential ECGS: a model study.

The objective of this investigation is to study, using a computer model, the torso volume conductor effects on body surface potential electrograms and body surface Laplacian electrograms. A spherical volume conductor model was used to approximate the torso and the heart. Myocardial electrical events were approximated by two distributed dipole-layers representing activation wavefronts propagating from the endocardium to the epicardium. The present computer simulation results indicate that the body surface Laplacian maps provide enhanced performance over the body surface potential maps in resolving the configurations of two activation wavefronts over the anterior wall of the heart.

Body Surface Potential Mapping

Factors affecting the accuracy of the boundary element method in the forward problem--I: Calculating surface potentials.

A comprehensive review of factors affecting the accuracy of the boundary element method (BEM) for calculating surface potentials is presented. A relative-error statistic is developed which is only sensitive to calculation errors that could affect the inverse solution for source position, and insensitive to errors that only affect the solution for source strength. The factors considered in this paper are: numerical approximations intrinsic to the BEM, such as constant-potential versus linear-potential basis functions and sharp-edged versus smooth-surfaced volumes; aspects of the volume conductor including the volume shape, density of surface elements, and element shape; source position and orientation; and effects of "refinements" in the numerical methods. The effects of these factors are considered in both smooth-shaped (spheres and spheroids) and sharp-edged (cubes) volume conductors. This represents the first attempt to assess the effects of many of these factors pertaining to the numerical methods commonly used in fields such as electrocardiography (ECG) and electroencephalography (EEG). Strategies for obtaining the most accurate solutions are presented.

Body Surface Potential Mapping