Interactive intraoperative localization using an infrared-based system.

Abstract

We discuss new methods of localizing and treating brain lesions for both the conventional method of a base-ring fixed to the patient's skull (referred to as frame-based procedures) and the new method of frameless procedures (no base ring). Frame-based procedures are used for finding a precise instrument position during neurosurgical procedures, such as stereotactic biopsy of deep-seated lesions, placing electrodes for functional stereotaxis or catheters with radioactive seeds for brachytherapy, or even the placement of a stereotactic retractor or endoscope for removal or internal decompression of lesions. In such procedures, the intraoperative image localization of instruments becomes useful as it tracks instruments as they travel through the preplanned trajectory. Additional intraoperative digitization of surgical instruments, e.g., bipolar suction, biopsy forceps, microscope, ultrasound probe, etc, can be achieved during the stereotactic resection of eloquent areas or deep intracranial lesions by adding an infrared-based system. Frameless procedures broaden the range of surgical approaches, image guidance planning, and operative procedures, since no ring is attached to the patient's head which might interfere with the surgical approach, and offers logistic advantages in scheduling diagnostic studies. Frameless diagnostic studies employ anatomical markers and/or surface matching techniques for data registration in the computer software surgical preplanning program. This simplifies scheduling of the procedures since the image study does not need to be acquired the same day as surgery. Frameless diagnostic studies allow for the use of more than one type of imaging data for planning and optimization of surgical procedures, and greatly improve patient tolerance and comfort during these procedures and during surgery, as compared with frame-based procedures.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L J Zamorano, L Nolte, A M Kadi, Z Jiang. 1993. Interactive intraoperative localization using an infrared-based system.. https://doi.org/10.1080/01616412.1993.11740150

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Outgrowing nerves in the foreleg of a mouse embryo as viewed by three-dimensional reconstruction from electron micrographs.

Electron micrographs from serial cross-sections of 12-day-old mouse forelegs were digitized and three-dimensional reconstruction of the data was carried out on an Apple Macintosh Quadra 700 computer using a program especially designed for this purpose. Two nerve endings of the palmar net of the median nerve were visualized together with their accompanying Schwann cells and the surrounding processes of fibroblasts. Naked axons invade straightly into the embryonic connective tissue and serve as contact guidance for the Schwann cells to follow. Fibroblasts with long processes extend around the axons with a parallel orientation. Contacts between axons and fibroblasts are occasionally observed. It is unclear whether the parallel orientation of nerve endings and fibroblast extensions have any biological significance.

Analog-Digital Conversion

The calculation of linear dimension and image area using a digitising tablet and personal computer.

An inexpensive image-area and perimeter-length measurement system consisting of a personal computer and digital graphics tablet is described. A study to assess the efficacy of the system has shown that accuracy and reproducibility of area measurement increase with increasing size of cross-sectional area. The system generally underestimated all derived areas by less than 2%. Reproducibility of measurement, as defined by the coefficient of variation, was typically less than 2%; the greatest inaccuracies and variability occurring with shapes of smaller cross-sectional area. The system seems to be the least accurate when it measures shapes with rectangular symmetry. Neither direction of digitisation nor operator skill seemed to influence the measurement accuracy of the system.

Analog-Digital Conversion