PubMed HealthSearch

PubMed · 7922243

Diagnostics and techniques.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1993. Diagnostics and techniques.. https://doi.org/10.1097/00041552-199311000-00021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pressure picture.

Explore the source record for details and available documents.

Blood Pressure Monitoring, Ambulatory

Factors confounding assessment of ambulatory blood pressure monitors, studied during formal evaluation of the Tycos Quiet-Trak.

The credibility of studies assessing ambulatory blood pressure monitoring (ABPM) devices will be enhanced by minimizing opportunities to manipulate the outcome through biased selection of patient volunteers, and by insuring that participants are representative of the target patient population. While subjecting the Welch Allyn Quiet-Trak to the British Hypertension Society (BHS) protocol, we examined the extent to which certain candidate characteristics might influence device assessment. The Quiet-Trak achieved an A grade overall. During its field testing, daytime physical activity measured with a wrist-mounted, piezoelectric accelerometer, influenced significantly the rate of measurement rejection. The tertiles of subjects with highest and lowest levels of daytime physical activity (64 +/- 16 and 35 +/- 10 activity units; P < .001) exhibited significantly different measurement rejection rates (10 +/- 3 and 3 +/- 2 daytime rejects; P < .001)). Most rejected readings occurred during episodes of high physical activity. During static evaluation (Phase V), the level of systolic BP influenced the accuracy of diastolic BP estimation; above 190 mm Hg systolic BP, estimates of diastolic BP differed significantly from manual measurements. Subjects' age and arm circumference influenced neither field nor static evaluation. Retrospective comparison of the study subjects with 120 consecutive ABPM clinic attenders revealed (1) that participants in field testing were younger, had lower BP but were equally active compared with clinic patients; and (2) that Phase V participants exhibited higher systolic (155 +/- 42 v 135 +/- 15 mm Hg; P < .001) but similar diastolic BP levels compared to controls. The reliability of ABPM validation protocols would be enhanced by: (a) incorporation of objective measurement of physical activity during field testing, demonstrating normal levels of activity; (b) requiring that field testing be conducted in representative patients rather than normal volunteers; and (c) a greater focus in both static and field testing on those levels of blood pressure that are relevant in clinical practice.

Blood Pressure Monitoring, Ambulatory